4-2 Temporary errors and Alarm detection algorithm
4-2-1 Temporary errors
Temporary errors occur during scanning operation and can be remedied by an operator. The temporary errors are displayed on
the PC screen through the driver and/or on the operator panel.
When a temporary error occurs, the scanner displays the following:
Function
No. Display
Power
LED
Description (supplement)
ON
Displays “U” or “J” and the error No. (0~8) alternately.
Example)
When error “U0” occurs, the scanner displays the following:
“U”
Æ
”SP”
Æ
“0” ………
The interval of changing the display is approximately 0.5 second.
When Scan or Send to button is pressed while the alarm is displayed, the scanner returns to the “Ready” display (Function
number display).
4-2-2 Alarms
Alarms require the maintenance conducted by an authorized service person. The following table shows the display and detection
algorithm for alarms. The alarms are displayed on a PC screen and/or on the operator panel (Function No. Display).
When an alarm occurs, the scanner displays the following on the operator panel:
Function
No. Display
Power
LED
Description (supplement)
ON
Displays “A”, “C”, “E”, “F”, “H”, or “L” and one of the alarms (0 ~ 9)
alternately.
The example shown in the left column is the case of Alarm “E0”.
The display sequence is:
“E”
Æ
”SP”
Æ
“0” ……
The interval of changing the display is approximately 0.5 second.
When Scan or Send to button is pressed while the alarm is displayed, the scanner returns to the “Ready” display (Function
number display).
4-2-3 Error Recovery Guide
If the application “Error Recovery Guide” (step (11) of Section 2.2.2) is installed in the PC, the corresponding error
name and error code are displayed on the PC screen when any error or scanner alarm comes up.
Detail code