Configuration
38
Programming Guide
Parameter
T02
Default
35 s
Value Range
0-60 s
Description/Function
Trunk port:
Specifies the maximum time allowed to the system after receiving
the notification of call disconnection from ISDN, before replying to
it.
Reference
None
Parameter
T03
Default
10 s
Value Range
0-60 s
Description/Function
Trunk port:
Specifies the maximum time that the system waits after sending the
request of call disconnection to ISDN, before receiving the reply to
it.
Reference
None
Parameter
T04
Default
10 s
Value Range
0-60 s
Description/Function
Trunk port:
Specifies the time to delay the announcement of call disconnection.
This setting is used when an announcement is given to the system
from ISDN before disconnecting the call.
Reference
None
Parameter
T05
Default
60 s
Value Range
0-300 s
Description/Function
Extension port:
Specifies the maximum time allowed to the system after receiving
the notification of incoming call from ISDN, before replying to it.
Reference
None
Summary of Contents for LX-TD500
Page 5: ...Configuration Programming Guide 5 Section 1 Configuration ...
Page 11: ...Configuration Programming Guide 11 1 2 14 CPU Card Information 1 2 15 TSW Card Configuration ...
Page 75: ...System Programming Guide 75 Section 2 System ...
Page 150: ...System 150 Programming Guide ...
Page 151: ...Group Programming Guide 151 Section 3 Group ...
Page 152: ...Group 152 Programming Guide 3 1 Group Used to assign various group parameters ...
Page 196: ...Group 196 Programming Guide ...
Page 197: ...Line Programming Guide 197 Section 4 Line ...
Page 199: ...Line Programming Guide 199 4 2 Trunk Line Used to assign various parameters for trunk lines ...
Page 249: ...Features Programming Guide 249 Section 5 Features ...
Page 281: ...Toll Restriction Programming Guide 281 Section 6 Toll Restriction ...
Page 287: ...ARS Automatic Route Selection Programming Guide 287 Section 7 ARS Automatic Route Selection ...
Page 296: ...ARS Automatic Route Selection 296 Programming Guide ...
Page 297: ...Private Network Programming Guide 297 Section 8 Private Network ...
Page 301: ...DID Dial Programming Guide 301 Section 9 DID Dial ...
Page 309: ...Maintenance Programming Guide 309 Section 10 Maintenance ...
Page 336: ...Maintenance 336 Programming Guide ...
Page 337: ...Programming Error Messages Programming Guide 337 Section 11 Programming Error Messages ...
Page 353: ...Default Values Programming Guide 353 Section 12 Default Values ...