Line
246
Programming Guide
Parameter
ISDN Bearer Mode
Default
Automatic
Value Range
1.
Automatic
2.
Speech
3.
3.1 KHz Audio
Description/Function
Specifies the ISDN Bearer Mode on an ISDN extension basis.
Note
•
When "Automatic" (Default) is selected, Bearer Mode is set
automatically depending on the type of extension telephone
as follows: PT – Speech, SLT – 3.1 KHz Audio, ISDN
extension – depending on the bearer mode of the ISDN
extension.
Reference
• 2.1 ISDN Features (F/G)
– Integrated Services Digital Network (ISDN)
Parameter
Numbering Plan ID
Default
Default
Value Range
1.
Default
2.
Unknown
3.
ISDN / Telephony
4.
National Standard
5.
Private
Description/Function
Specifies the Numbering Plan ID applied to the outgoing /
incoming CO calls via ISDN.
Reference
None
Parameter
Type of Number
Default
Default
Value Range
1.
Default
2.
Unknown
3.
International
4.
National
5.
Network Specific
6.
Subscriber
Description/Function
Specifies the Type of Number applied to the outgoing / incoming
CO calls via ISDN.
Reference
None
Summary of Contents for LX-TD500
Page 5: ...Configuration Programming Guide 5 Section 1 Configuration ...
Page 11: ...Configuration Programming Guide 11 1 2 14 CPU Card Information 1 2 15 TSW Card Configuration ...
Page 75: ...System Programming Guide 75 Section 2 System ...
Page 150: ...System 150 Programming Guide ...
Page 151: ...Group Programming Guide 151 Section 3 Group ...
Page 152: ...Group 152 Programming Guide 3 1 Group Used to assign various group parameters ...
Page 196: ...Group 196 Programming Guide ...
Page 197: ...Line Programming Guide 197 Section 4 Line ...
Page 199: ...Line Programming Guide 199 4 2 Trunk Line Used to assign various parameters for trunk lines ...
Page 249: ...Features Programming Guide 249 Section 5 Features ...
Page 281: ...Toll Restriction Programming Guide 281 Section 6 Toll Restriction ...
Page 287: ...ARS Automatic Route Selection Programming Guide 287 Section 7 ARS Automatic Route Selection ...
Page 296: ...ARS Automatic Route Selection 296 Programming Guide ...
Page 297: ...Private Network Programming Guide 297 Section 8 Private Network ...
Page 301: ...DID Dial Programming Guide 301 Section 9 DID Dial ...
Page 309: ...Maintenance Programming Guide 309 Section 10 Maintenance ...
Page 336: ...Maintenance 336 Programming Guide ...
Page 337: ...Programming Error Messages Programming Guide 337 Section 11 Programming Error Messages ...
Page 353: ...Default Values Programming Guide 353 Section 12 Default Values ...