Programming Error Messages
Programming Guide
347
E5010
Specify the code.
The account code also must be entered when the TRS Level is assigned and the TRS
Level also must be deleted when the account code is deleted.
E5011
Specify the leading digits.
The ARS leading dial also must be entered when the Route Plan Table No. is assigned
and the Route Plan Table No. also must be deleted when the leading dial is deleted.
E5022
File format error.(Line: X)
Format (syntax) error was found at the indicated line (X) in the database file.
E6001
Too long TRS Deny or Exception dial.
TRS Deny or Exception dial can be registered up to 10 digits consisting of 0–9,
,
#
or X (a wild card).
E6002
Cannot assign more than 400 TRS deny codes.
There is a limit of 400 toll restriction deny codes per system.
E6003
Cannot assign more than 200 TRS exception codes.
There is a limit of 200 toll restriction exception codes per system.
E7001
Invalid arrangement of time zones.
Each successive ARS time zone must be later in time. Namely, this pattern must be
followed: Time-A < Time-B < Time-C < Time-D.
E7002
Assign both trunk group number and modification table number.
Cannot assign just trunk group number or just modification table number.
Both must be assigned as a pair under ARS routing plan.
E9001
Invalid directory number for DID destination.
There are seven possible destinations for DID calls:
(1) An extension, (2) an external pager (TAFAS), (3) an OGM group,
(4) a remote extension, (5) an extension group, (6) an incoming group or
(7) a phantom extension.
E9002
Page length must be 4 lines more than Skip Perforation.
The difference of Page Length and Skip Perforation must be more than 4 lines.
E9003
Trunk or extension card duplicated.
Under Power Failure Transfer, a trunk card or an extension card can be specified only
once.
E9004
Assign both trunk card and extension card.
Cannot assign just trunk card or just extension card.
Both must be assigned as a pair under Power Failure Transfer.
E9005
Time or date format error.
The invalid value of time or date is entered.
E9006
Invalid System Programming password.
Please assign the 4 through 7-digit System Programming password of alphanumeric
characters.
Error Code
Error Message
Description
Summary of Contents for LX-TD500
Page 5: ...Configuration Programming Guide 5 Section 1 Configuration ...
Page 11: ...Configuration Programming Guide 11 1 2 14 CPU Card Information 1 2 15 TSW Card Configuration ...
Page 75: ...System Programming Guide 75 Section 2 System ...
Page 150: ...System 150 Programming Guide ...
Page 151: ...Group Programming Guide 151 Section 3 Group ...
Page 152: ...Group 152 Programming Guide 3 1 Group Used to assign various group parameters ...
Page 196: ...Group 196 Programming Guide ...
Page 197: ...Line Programming Guide 197 Section 4 Line ...
Page 199: ...Line Programming Guide 199 4 2 Trunk Line Used to assign various parameters for trunk lines ...
Page 249: ...Features Programming Guide 249 Section 5 Features ...
Page 281: ...Toll Restriction Programming Guide 281 Section 6 Toll Restriction ...
Page 287: ...ARS Automatic Route Selection Programming Guide 287 Section 7 ARS Automatic Route Selection ...
Page 296: ...ARS Automatic Route Selection 296 Programming Guide ...
Page 297: ...Private Network Programming Guide 297 Section 8 Private Network ...
Page 301: ...DID Dial Programming Guide 301 Section 9 DID Dial ...
Page 309: ...Maintenance Programming Guide 309 Section 10 Maintenance ...
Page 336: ...Maintenance 336 Programming Guide ...
Page 337: ...Programming Error Messages Programming Guide 337 Section 11 Programming Error Messages ...
Page 353: ...Default Values Programming Guide 353 Section 12 Default Values ...