Programming Error Messages
Programming Guide
343
E2005
Maximum entry number of System Speed Dialing exceeded.
The system provides up to 1000 / tenant, 2000 / system of System Speed Dialing entries
available to all extension users.
E2006
Cannot change System Speed Dialing Entries Maximum.
Please delete System Speed Dialing entries until there is less than the setting you want.
Then set System Speed Dialing Entries Maximum once again.
E2007
Invalid directory number for manager extension.
Only DN of an extension can be assigned as a manager extension. (FDN cannot be
assigned.)
E2008
Feature number is too long.
Feature numbers "Hundred Block Extension" or "Other PBX" can be set as the leading
1 or 2 digits of the extension number.
E2009
Cannot delete the Hundred Block Extension, which is currently in use as DN or
FDN.
Cannot delete the hundred block number. It's already used as DN or FDN. Please delete
the hundred block number after you remove the registrations of DN or FDN.
E2010
Feature number duplicated.
Feature numbers can be from 1 to 4 digits and shouldn't be any conflicts.
The following are examples of feature number conflicts.
Examples: N and NX, NXX / NM and NML ( NL is allowed.)
E2011
Out of range.
Overflow Timer should be assigned in the range of Second: 5-180.
"None" shows that Overflow Timer doesn't work.
E2012
Trunk group number duplicated.
Each trunk group in the Local Hunt Sequence must have a unique number.
E2013
Invalid directory number for Operator FDN
Only FDN of an extension group and incoming group can be assigned as an Operator
FDN.
E3001
Invalid directory number for intercept destination.
There are seven possible destinations for intercepted calls:
(1) An extension, (2) an external pager (TAFAS), (3) an OGM group,
(4) an extension group, (5) an incoming group, (6) a phantom extension, or (7) an ISDN
extension (except the wild card character "X")
E3002
Invalid directory number for overflow destination.
Only DN of an extension or FDN of an extension group, an incoming group, a phantom
extension or an external pager (TAFAS) can be assigned as an overflow destination.
However, the type of DN / FDN assignable depends on "Group Type."
E3003
Invalid directory number for UCD supervisor extension.
Only DN of an extension can be assigned as UCD supervisor extension.
Error Code
Error Message
Description
Summary of Contents for LX-TD500
Page 5: ...Configuration Programming Guide 5 Section 1 Configuration ...
Page 11: ...Configuration Programming Guide 11 1 2 14 CPU Card Information 1 2 15 TSW Card Configuration ...
Page 75: ...System Programming Guide 75 Section 2 System ...
Page 150: ...System 150 Programming Guide ...
Page 151: ...Group Programming Guide 151 Section 3 Group ...
Page 152: ...Group 152 Programming Guide 3 1 Group Used to assign various group parameters ...
Page 196: ...Group 196 Programming Guide ...
Page 197: ...Line Programming Guide 197 Section 4 Line ...
Page 199: ...Line Programming Guide 199 4 2 Trunk Line Used to assign various parameters for trunk lines ...
Page 249: ...Features Programming Guide 249 Section 5 Features ...
Page 281: ...Toll Restriction Programming Guide 281 Section 6 Toll Restriction ...
Page 287: ...ARS Automatic Route Selection Programming Guide 287 Section 7 ARS Automatic Route Selection ...
Page 296: ...ARS Automatic Route Selection 296 Programming Guide ...
Page 297: ...Private Network Programming Guide 297 Section 8 Private Network ...
Page 301: ...DID Dial Programming Guide 301 Section 9 DID Dial ...
Page 309: ...Maintenance Programming Guide 309 Section 10 Maintenance ...
Page 336: ...Maintenance 336 Programming Guide ...
Page 337: ...Programming Error Messages Programming Guide 337 Section 11 Programming Error Messages ...
Page 353: ...Default Values Programming Guide 353 Section 12 Default Values ...