Configuration
Programming Guide
19
Parameter
First Dial Timer
Default
1.0 s
Value Range
0.5-8.0 s in 0.5 s increments
Description/Function
On outgoing CO calls, the system waits at least 1.0 second after
seizing the CO line, before sending the dialing digits to the Central
Office by default.
This allows the Central Office enough time to accept the dialing
digits correctly.
Specifies the appropriate value depending on the requirements of
your local Central Office.
Reference
None
Parameter
% Break
Default
60%
Value Range
1.
60%
2.
67%
Description/Function
Specifies the % break for pulse digits.
This is the ratio between on-hook and off-hook signals during digit
transmission.
Reference
None
Parameter
Flash Time
Default
608 ms
Value Range
16-4080 ms in 16 ms increments
Description/Function
Specifies the length of Flash signal which the system sends to the
local Central Office.
Notes
•
This assignment is helpful when you need finer resolution in
the flash time than the choices presented in "Flash Time" in
"3-1 Trunk Group" screen. To activate this assignment, set
"Flash Time" in "3-1 Trunk Group" screen to 80 ms.
•
This assignment is necessary when your Central Office
requires a Flash Time not listed in "Flash Time" in "3-1
Trunk Group" screen.
Reference
• 3.2
Trunk Group (P/G)
Summary of Contents for LX-TD500
Page 5: ...Configuration Programming Guide 5 Section 1 Configuration ...
Page 11: ...Configuration Programming Guide 11 1 2 14 CPU Card Information 1 2 15 TSW Card Configuration ...
Page 75: ...System Programming Guide 75 Section 2 System ...
Page 150: ...System 150 Programming Guide ...
Page 151: ...Group Programming Guide 151 Section 3 Group ...
Page 152: ...Group 152 Programming Guide 3 1 Group Used to assign various group parameters ...
Page 196: ...Group 196 Programming Guide ...
Page 197: ...Line Programming Guide 197 Section 4 Line ...
Page 199: ...Line Programming Guide 199 4 2 Trunk Line Used to assign various parameters for trunk lines ...
Page 249: ...Features Programming Guide 249 Section 5 Features ...
Page 281: ...Toll Restriction Programming Guide 281 Section 6 Toll Restriction ...
Page 287: ...ARS Automatic Route Selection Programming Guide 287 Section 7 ARS Automatic Route Selection ...
Page 296: ...ARS Automatic Route Selection 296 Programming Guide ...
Page 297: ...Private Network Programming Guide 297 Section 8 Private Network ...
Page 301: ...DID Dial Programming Guide 301 Section 9 DID Dial ...
Page 309: ...Maintenance Programming Guide 309 Section 10 Maintenance ...
Page 336: ...Maintenance 336 Programming Guide ...
Page 337: ...Programming Error Messages Programming Guide 337 Section 11 Programming Error Messages ...
Page 353: ...Default Values Programming Guide 353 Section 12 Default Values ...