150
orbitalum tools GmbH
, D-78224 Singen, www.orbitalum.com, Phone +49 (0) 77 31 792-0
(14.01.21) OW_ORBIMAT_300SW_BA_852060202_00_EN
ORBIMAT 300 SW
EnGLISH
10. MAINTENANCE AND TROUBLESHOOTING
10.1 Instructions for care
X
Do not use lubricants or sliding agents.
X
Ensure that no dirt particles or small items enter the transmission (head inside) (the transmission is open at the
head end for design reasons).
X
If the surfaces are soiled, use only residue-free cleaning agents for cleaning.
10.2 Maintenance and care
The following instructions for care depend, if not stated otherwise, strongly on the usage of the welding power supply.
INTERVAL
ACTIVITY
Daily
X
Check the coolant level of the external cooling unit and, if necessary, top
up.
Frequent topping up of the coolant may be necessary if the weld heads are
changed frequently.
1. After changing a weld head, ensure that it is completely filled with coolant
(let run for approx. 3 minutes – button: GAS/Coolant).
1. Check the coolant level and refill if necessary.
X
If anti-freeze is used: Supplement with the coolant appropriately.
X
Wipe off the display with a slightly damp cloth. Do not use cleaning agents.
Monthly
X
Clean the machine fully from the outside.
X
Check the power cable, power plug and machine for mechanical damage.
X
Clean the weld heads and check the mains cable.
Recommendation:
X
Carry out motor calibration (even if the weld heads are suspected to be run-
ning properly).
Every six months
1. Completely pump out coolant from the external cooling unit.
2. Add fresh tap water and pump out all of this filling as well.
3. Fill the tank with coolant OCL-30.
Annually
X
Have inverter calibration carried out by the Orbitalum Service. Have the
BGV-A3 test carried out by Orbitalum or a certified body.