(14.01.21) OW_ORBIMAT_300SW_BA_852060202_00_EN
ORBITALUM TOOLS GMBH
,
D-78224 SINGEN, WWW.ORBITALUM.COM, PHONE +49 (0) 77 31 792-0 127
ORBIMAT 300 SW
EnGLISH
8.8.6
External monitor /HDMI
HDMI connection: Can be selected freely on the rear of the machine.
The machine display is not switched off when an additional monitor is connected.
8.9
Monitoring functions
8.9.1
General information
The machine monitors the following parameters:
• Gas quantity
• Coolant quantity
• Temperature of the power section
If the (permanently set) limit values are exceeded, the machine switches off automatically.
With the following parameters, the limit values (minimum and maximum values for warning and procedure abortion) are
set based on the procedure:
• Weld current
• Weld speed
• Arc voltage
In the case of overshooting or undershooting of the values for the warning message, a warning message is output, but
the running process is not interrupted.
In case of overshooting or undershooting of the values for procedure abortion, the running process is interrupted.
During the process, the following parameters are displayed for informational purposes:
• Mains voltage
• Coolant temperature
8.9.2
Adjusting limit values
X
In the main menu select "
System settings
" > "
Program settings
" > "
Limit adjustments
".
The parameters with the limit values appear in the display:
Minimum HP current abort
Downward deviation of the high-pulse current (HP).
If the specified deviation (-10 A) is reached, welding is
aborted.
Example: 60 A is programmed for the high-pulse current in
a sector. During the process, a value of 50 A (–10 A) is mea-
sured: The process is aborted.
The gas post purge time is still observed.
Minimum HP current alarm
Downward deviation of the high-pulse current (HP): If the
specified deviation (-5 A) is reached, a warning message
appears.
Abb. 20:
Limit values