(14.01.21) OW_ORBIMAT_300SW_BA_852060202_00_EN
ORBITALUM TOOLS GMBH
,
D-78224 SINGEN, WWW.ORBITALUM.COM, PHONE +49 (0) 77 31 792-0 101
ORBIMAT 300 SW
EnGLISH
7.5.1
Connecting Remote control/dummy plug
1. Connect the supplied dummy plug (4) or the optionally available remote control (5) (code 875 050 001) via the
adapter cable (6) (included in the scope of delivery of the remote control) to the remote control socket (7).
2. If a remote control is connected, the STOP button (8) must be unlocked as well.
3. The power source cannot be switched on without the dummy plug or unlocked remote control.
4
5
6
7
8
7.5.2
Switching on the power source
CAUTION!
X
Observe requirements for the
power supply: RCCB 30 mA.
1. Connect the machine to the mains network.
2. The Off button (red) (9) lights up as soon as the ma-
chine is connected to the mains network.
3. Switch on the ORBIMAT at the green main switch (10).
The operating system is loaded and the main menu
appears in the display (11).
Problems while switching on
Does the machine not start the first time it is switched on?
X
Check whether the pilot light in the main switch is lit up.
Is the pilot light not lit up?
There is a problem with the power supply (no voltage, plug not inserted).
X
Check whether the power plug is properly inserted.
X
Have the power supply checked.
Is the STOP indicator on the front panel lit up?
With external remote control connected: EMERGENCY-STOP switch is pressed.
1. Unlock EMERGENCY-STOP switch by turning it counterclockwise.
2. Switch off machine.
3. Wait at least 5 seconds and then switch machine on again.
9
10
11