14-31
14 Serial Communications
CP2E CPU Unit Software User’s Manual(W614)
14
-5 Serial PLC
Lin
ks
14
14-5-4 Oper
at
ing Specifications
z
Complete Link
The data from all nodes in the Serial PLC Links are reflected in both the Polling Unit and the Polled
Units.
The only exceptions are the addresses of Polled Units that are not present in the network. These
data areas are undefined in all nodes.
Example: Complete Link Method, Highest Unit Number:
3
In the following diagram, Polled Unit No. 2 is a Unit not present in the network, so the area allocated
for Polled Unit No. 2 is undefined in all nodes.
Example for Ten Link Words (Maximum Number of Words)
Each CPU Unit (either CP2E, CP1E, CP1L, CP1H, or CJ2M) sends data to the same words in all
other CPU Units for the Polling Unit and all Polled Units. Data is sent between the words that are
allocated to the Polling Unit and Polled Units according to unit numbers.
Po l l i n g U n i t
Local area
Polled Unit
N
o. 0
Polled Unit
N
o. 1
Polled Unit
N
o. 3
Undefined
(
N
ot
u
sed)
(
N
ot
u
sed)
(
N
ot
u
sed)
(
N
ot
u
sed)
Polling Unit
Local area
Po l l e d U n i t
N
o. 0
Polled Unit
N
o. 1
Polled Unit
N
o. 3
Undefined
(
N
ot
u
sed)
(
N
ot
u
sed)
(
N
ot
u
sed)
(
N
ot
u
sed)
Polling Unit
Local area
Polled Unit
N
o. 0
Po l l e d U n i t
N
o. 1
Polled Unit
N
o. 3
Undefined
(
N
ot
u
sed)
(
N
ot
u
sed)
(
N
ot
u
sed)
(
N
ot
u
sed)
Polling Unit
Local area
Polled Unit
N
o. 0
Polled Unit
N
o. 1
Po l l e d U n i t
N
o. 3
Undefined
(
N
ot
u
sed)
(
N
ot
u
sed)
(
N
ot
u
sed)
(
N
ot
u
sed)
CP2E CPU Unit
(Polling Unit)
CP2E CPU Unit
(Polled Unit No. 0)
S
eri
a
l PLC Link Word
s
S
eri
a
l PLC Link Word
s
S
eri
a
l PLC Link Word
s
S
eri
a
l PLC Link Word
s
No.0
No.1
No.2
No.3
No.4
No.5
No.6
No.7
No.0
No.1
No.2
No.3
No.4
No.5
No.6
No.7
No.0
No.1
No.2
No.3
No.4
No.5
No.6
No.7
No.0
No.1
No.2
No.3
No.4
No.5
No.6
No.7
CP1L CPU Unit
(Polled Unit No. 1)
Ex
a
mple: CJ2M CPU Unit
(Polled Unit No. 2)
CIO 200 to 209
CIO 210 to 219
CIO 220 to 229
CIO 230 to 239
CIO 240 to 249
CIO 250 to 259
CIO 260 to 269
CIO 270 to 279
CIO 280 to 289
CIO 200 to 209
CIO 210 to 219
CIO 220 to 229
CIO 230 to 239
CIO 240 to 249
CIO 250 to 259
CIO 260 to 269
CIO 270 to 279
CIO 280 to 289
CIO 3100 to 3109
CIO 3110 to 3119
CIO 3120 to 3129
CIO 3130 to 3139
CIO 3140 to 3149
CIO 3150 to 3159
CIO 3160 to 3169
CIO 3170 to 3179
CIO 3180 to 3189
CIO 3100 to 3109
CIO 3110 to 3119
CIO 3120 to 3129
CIO 3130 to 3139
CIO 3140 to 3149
CIO 3150 to 3159
CIO 3160 to 3169
CIO 3170 to 3179
CIO 3180 to 3189
Summary of Contents for SYSMAC CP Series
Page 3: ......
Page 32: ...1 Overview 1 4 CP2E CPU Unit Software User s Manual W614 ...
Page 44: ...3 CPU Unit Operation 3 8 CP2E CPU Unit Software User s Manual W614 ...
Page 116: ...6 I O Allocation 6 8 CP2E CPU Unit Software User s Manual W614 ...
Page 144: ...7 PLC Setup 7 28 CP2E CPU Unit Software User s Manual W614 ...
Page 170: ...10 Interrupts 10 14 CP2E CPU Unit Software User s Manual W614 ...
Page 200: ...11 High speed Counters 11 30 CP2E CPU Unit Software User s Manual W614 ...
Page 272: ...12 Pulse Outputs 12 72 CP2E CPU Unit Software User s Manual W614 ...
Page 278: ...13 PWM Outputs 13 6 CP2E CPU Unit Software User s Manual W614 ...
Page 460: ...18 Programming Device Operations 18 28 CP2E CPU Unit Software User s Manual W614 ...
Page 576: ...Revision 2 CP2E CPU Unit Software User s Manual W614 ...
Page 577: ......