7-17
7 PLC Setup
CP2E CPU Unit Software User’s Manual(W614)
7
-2 PLC
Setup Settings
7
7-2
-7 Built-in I
nputs
4
Use high-speed counter
3
Do not use.
Do not use.
When power is turned ON
Use.
4-1
Counting mode
Linear mode
Linear mode
At start of operation
Circular mode
4-1-1
Circular Max. Count
0
0
At start of operation
:
4,294,967,295
4-2
Reset
Software reset
Software reset
When power is turned ON
Software reset (comparing)
4-
3
Input Setting
Increment pulse input
Increment pulse input
When power is turned ON
5
Use high-speed counter 4
Do not use.
Do not use.
When power is turned ON
Use.
5-1
Counting mode
Linear mode
Linear mode
At start of operation
Circular mode
5-1-1
Circular Max. Count
0
0
At start of operation
:
4,294,967,295
5-2
Reset
Software reset
Software reset
When power is turned ON
Software reset (comparing)
5-
3
Input Setting
Increment pulse input
Increment pulse input
When power is turned ON
6
Use high-speed counter 5
Do not use.
Do not use.
When power is turned ON
Use.
6-1
Counting mode
Linear mode
Linear mode
At start of operation
Circular mode
6-1-1
Circular Max. Count
0
0
At start of operation
:
4,294,967,295
6-2
Reset
Software reset
Software reset
When power is turned ON
Software reset (comparing)
6-
3
Input Setting
Increment pulse input
Increment pulse input
When power is turned ON
Interrupt Input Settings
Name
Default
Possible settings
When setting is read by
CPU Unit
1
IN2: CIO 0.02
Normal
Normal
When power is turned ON
Interrupt
Quick
2
IN
3
: CIO 0.0
3
Normal
Normal
When power is turned ON
Interrupt
Quick
3
IN4: CIO 0.04
Normal
Normal
When power is turned ON
Interrupt
Quick
4
IN5: CIO 0.05
Normal
Normal
When power is turned ON
Interrupt
Quick
5
IN6: CIO 0.06
Normal
Normal
When power is turned ON
Interrupt
Quick
6
IN7: CIO 0.07
Normal
Normal
When power is turned ON
Interrupt
Quick
Name
Default
Possible settings
When setting is read by
CPU Unit
Summary of Contents for SYSMAC CP Series
Page 3: ......
Page 32: ...1 Overview 1 4 CP2E CPU Unit Software User s Manual W614 ...
Page 44: ...3 CPU Unit Operation 3 8 CP2E CPU Unit Software User s Manual W614 ...
Page 116: ...6 I O Allocation 6 8 CP2E CPU Unit Software User s Manual W614 ...
Page 144: ...7 PLC Setup 7 28 CP2E CPU Unit Software User s Manual W614 ...
Page 170: ...10 Interrupts 10 14 CP2E CPU Unit Software User s Manual W614 ...
Page 200: ...11 High speed Counters 11 30 CP2E CPU Unit Software User s Manual W614 ...
Page 272: ...12 Pulse Outputs 12 72 CP2E CPU Unit Software User s Manual W614 ...
Page 278: ...13 PWM Outputs 13 6 CP2E CPU Unit Software User s Manual W614 ...
Page 460: ...18 Programming Device Operations 18 28 CP2E CPU Unit Software User s Manual W614 ...
Page 576: ...Revision 2 CP2E CPU Unit Software User s Manual W614 ...
Page 577: ......