12 Pulse Outputs
12-40
CP2E CPU Unit Software User’s Manual(W614)
The following examples show how the operation patterns are affected by the origin detection method
and origin search operating mode.
These examples have a CW origin search direction. (The search direction and Limit Input Signal direc-
tion would be different for an origin search in the CCW direction.)
Method 0 is the recommended method for reversal mode 1 (Inverse 1).
z
Using Reversal Mode 1 (Inverse 1)
Operation Patterns for Origin Search Operating Mode and Origin
Detection Method Settings
Origin search operation
Origin detection method
Reversal mode 1 (Inverse 1)
0: Origin Proximity Input Signal
reversal required.
(Recommended method)
1: Origin Proximity Input Signal
reversal not required.
2: Origin Proximity Input Signal not
used.
1
0
1
0
CC
W
CC
W
CC
W
C
W
C
W
C
W
Origin Proximity
Inp
u
t Signal
Origin Inp
u
t Signal
P
u
lse o
u
tp
u
t
High speed for origin search
Proximity speed for origin search
Start
Start
Start
Stop
Stop
Stop
C
W
Limit Inp
u
t Signal (See note.)
Note
W
hen the Limit Inp
u
t Signal is recei
v
ed, the motor stops
w
itho
u
t
deceleration, re
v
erses direction, and accelerates.
1
0
1
0
CC
W
CC
W
CC
W
C
W
C
W
C
W
Origin Proximity
Inp
u
t Signal
Origin Inp
u
t Signal
P
u
lse o
u
tp
u
t
Note
W
hen the Limit Inp
u
t Signal is recei
v
ed, the motor stops
w
itho
u
t
deceleration, re
v
erses direction, and accelerates.
Start
Start
Start
Stop
Stop
Stop
C
W
Limit Inp
u
t Signal (See note.)
1
0
CC
W
CC
W
CC
W
C
W
C
W
C
W
Origin Inp
u
t Signal
P
u
lse o
u
tp
u
t
Proximity speed for origin search
Start
Start
Start
Stop
Stop
Stop
C
W
Limit Inp
u
t Signal (See note.)
Note
W
hen the Limit Inp
u
t Signal is recei
v
ed, the motor stops
w
itho
u
t
deceleration, re
v
erses direction, and accelerates.
Summary of Contents for SYSMAC CP Series
Page 3: ......
Page 32: ...1 Overview 1 4 CP2E CPU Unit Software User s Manual W614 ...
Page 44: ...3 CPU Unit Operation 3 8 CP2E CPU Unit Software User s Manual W614 ...
Page 116: ...6 I O Allocation 6 8 CP2E CPU Unit Software User s Manual W614 ...
Page 144: ...7 PLC Setup 7 28 CP2E CPU Unit Software User s Manual W614 ...
Page 170: ...10 Interrupts 10 14 CP2E CPU Unit Software User s Manual W614 ...
Page 200: ...11 High speed Counters 11 30 CP2E CPU Unit Software User s Manual W614 ...
Page 272: ...12 Pulse Outputs 12 72 CP2E CPU Unit Software User s Manual W614 ...
Page 278: ...13 PWM Outputs 13 6 CP2E CPU Unit Software User s Manual W614 ...
Page 460: ...18 Programming Device Operations 18 28 CP2E CPU Unit Software User s Manual W614 ...
Page 576: ...Revision 2 CP2E CPU Unit Software User s Manual W614 ...
Page 577: ......