Appendices
A-84
CP2E CPU Unit Software User’s Manual(W614)
A51
8
to
A520
---
Operation End Time
The time that operation stopped as a
result of changing the operating mode
to PROGRAM mode is stored here in
BCD.
A51
8
.00 to A51
8
.07: Seconds (00 to
59)
A51
8
.0
8
to A51
8
.15: Minutes (00 to
59)
A519.00 to A519.07: Hour (00 to 2
3
)
A519.0
8
to A519.15: Day of month (01
to
3
1)
A520.00 to A520.07: Month (01 to 12)
A520.0
8
to A520.15: Year (00 to 99)
Note 1
If an error occurs in operation,
the time of the error will be
stored. If the operating mode
is then changed to
PROGRAM mode, the time
that PROGRAM mode was
entered will be stored.
2
In an E
-type CPU Unit or
when time alignment cannot
be executed with an
N/S
-type CPU Unit, the
data will be for 1:01.01 on
Sunday January 1, 2001.
See Function col-
umn.
Retained
Retained
See Function
column.
A521
00
to
07
Serial Port 1 (EX)
Error Flags (CP2E
N
-type CPU Unit
only)
These flags indicate what kind of error
has occurred at the serial port 1 (EX).
•
They are automatically turned OFF
when the serial port 1 (EX) is
restarted.
•
Only bit 5 (timeout error) is valid in
NT Link mode.
•
Serial PLC Link Polling Unit:
Bit 05: ON for timeout error.
Serial PLC Link Polled Unit:
Bit 02: ON for parity error.
Bit 0
3
: ON for framing error.
Bit 04: ON for overrun error.
These bits can be cleared by the
CX-Programmer.
Bits 00 and 01: Not
used.
Bit 02: ON for parity
error.
Bit 0
3
: ON for fram-
ing error.
Bit 04: ON for over-
run error.
Bit 05: ON for time-
out error.
Bits 06 and 07: Not
used.
Retained
Cleared
Refreshed
when commu-
nication error
occurs.
A526
00
Serial Port 1/
Built-in RS-2
3
2C Port
Restart Bit
Turn ON this bit to restart the serial
port 1 or built-in RS-2
3
2C port.
Note
This bit is turned OFF automati-
cally when the restart processing
is completed.
OFF to ON: Restart
Retained
Cleared
---
01
Serial Port 2/
Bult-in RS-4
8
5 Port
Restart Bit (CP2E
N
3
0/40/60 or
S
-type CPU Unit
only)
Turn ON this bit to restart the serial
port 2 or built-in RS-4
8
5 port.
Note
This bit is turned OFF automati-
cally when the restart processing
is completed.
OFF to ON: Restart
Retained
Cleared
---
02
Serial Port 1 (EX)
Restart Bit (CP2E
N
-type CPU Unit
only)
Turn ON this bit to restart the serial
port 1 (EX).
Note
This bit is turned OFF automati-
cally when the restart processing
is completed.
OFF to ON: Restart
Retained
Cleared
---
Address
Name
Function
Settings
Status
after
mode
change
Status at
startup
Write
timing
Related
flags,
settings
Words
Bits
Summary of Contents for SYSMAC CP Series
Page 3: ......
Page 32: ...1 Overview 1 4 CP2E CPU Unit Software User s Manual W614 ...
Page 44: ...3 CPU Unit Operation 3 8 CP2E CPU Unit Software User s Manual W614 ...
Page 116: ...6 I O Allocation 6 8 CP2E CPU Unit Software User s Manual W614 ...
Page 144: ...7 PLC Setup 7 28 CP2E CPU Unit Software User s Manual W614 ...
Page 170: ...10 Interrupts 10 14 CP2E CPU Unit Software User s Manual W614 ...
Page 200: ...11 High speed Counters 11 30 CP2E CPU Unit Software User s Manual W614 ...
Page 272: ...12 Pulse Outputs 12 72 CP2E CPU Unit Software User s Manual W614 ...
Page 278: ...13 PWM Outputs 13 6 CP2E CPU Unit Software User s Manual W614 ...
Page 460: ...18 Programming Device Operations 18 28 CP2E CPU Unit Software User s Manual W614 ...
Page 576: ...Revision 2 CP2E CPU Unit Software User s Manual W614 ...
Page 577: ......