![background image](http://html.mh-extra.com/html/omron/sysmac-cp-series/sysmac-cp-series_user-manual_742262543.webp)
A-83
Appendices
CP2E CPU Unit Software User’s Manual(W614)
A-2 A
u
xil
iar
y Area A
llocation
s b
y
Ad
dress
App
A-2-2 Read/Wr
ite W
ords
A512
to
A51
3
---
Power Interruption
Time
These words contain the time at which
the power was interrupted. The con-
tents are updated every time that the
power is interrupted. The data is
stored in BCD.
A512.00 to A512.07: Second (00 to
59)
A512.0
8
to A512.15: Minute (00 to 59)
A51
3
.00 to A51
3
.07: Hour (00 to 2
3
)
A51
3
.0
8
to A51
3
.15: Day of month (01
to
3
1)
Note 1
These words are not cleared
at startup.
2
In an E
-type CPU Unit or
when time alignment cannot
be executed with an
N/S
-type CPU Unit, the
data will be for 1:01.01 on
Sunday January 1, 2001.
See Function col-
umn.
Retained
Retained
Written at
power
interruption.
A514
---
Number of Power
Interruptions
Contains the number of times that
power has been interrupted since the
power was first turned ON. The data is
stored in binary. To reset this value,
overwrite the current value with 0000.
0000 to FFFF hex
Retained
Retained
Refreshed
when power is
turned ON.
A515
to
A517
---
Operation Start Time
The time that operation started as a
result of changing the operating mode
to RUN or MONITOR mode is stored
here in BCD.
A515.00 to A515.07: Seconds (00 to
59)
A515.0
8
to A515.15: Minutes (00 to
59)
A516.00 to A516.07: Hour (00 to 2
3
)
A516.0
8
to A516.15: Day of month (01
to
3
1)
A517.00 to A517.07: Month (01 to 12)
A517.0
8
to A517.15: Year (00 to 99)
Note 1
The previous start time is
stored after turning ON the
power supply until operation is
started.
2
In an E
-type CPU Unit or
when time alignment cannot
be executed with an
N/S
-type CPU Unit, the
data will be for 1:01.01 on
Sunday January 1, 2001.
See Function col-
umn.
Retained
Retained
See Function
column.
Address
Name
Function
Settings
Status
after
mode
change
Status at
startup
Write
timing
Related
flags,
settings
Words
Bits
Summary of Contents for SYSMAC CP Series
Page 3: ......
Page 32: ...1 Overview 1 4 CP2E CPU Unit Software User s Manual W614 ...
Page 44: ...3 CPU Unit Operation 3 8 CP2E CPU Unit Software User s Manual W614 ...
Page 116: ...6 I O Allocation 6 8 CP2E CPU Unit Software User s Manual W614 ...
Page 144: ...7 PLC Setup 7 28 CP2E CPU Unit Software User s Manual W614 ...
Page 170: ...10 Interrupts 10 14 CP2E CPU Unit Software User s Manual W614 ...
Page 200: ...11 High speed Counters 11 30 CP2E CPU Unit Software User s Manual W614 ...
Page 272: ...12 Pulse Outputs 12 72 CP2E CPU Unit Software User s Manual W614 ...
Page 278: ...13 PWM Outputs 13 6 CP2E CPU Unit Software User s Manual W614 ...
Page 460: ...18 Programming Device Operations 18 28 CP2E CPU Unit Software User s Manual W614 ...
Page 576: ...Revision 2 CP2E CPU Unit Software User s Manual W614 ...
Page 577: ......