Allocating Built-in Input
T
er
m
in
als
z
E14 or N14 CPU Units
Note 1
The same pulse inputs must be used for high-speed counter 0 and high-speed counter 1.
2
High-speed counter 2 cannot be used if the input setting of high-speed counter 0 or high-speed counter 1
is set for differential phase inputs (4×), pulse + direction inputs, or up/down pulse inputs.
The input terminals 00 to 11 of CIO 0 and 00 to 01 of CIO 1 are used for input interrupts, quick-
response inputs, high-speed counters, origin searches and normal inputs. Therefore, do not use the
input terminals repeatedly. For example, if quick-response input 2 is used, then input terminal 02 is
occupied, so it cannot be used for normal input 2, input interrupt 2, quick-response input 2, counter 2
(increment), counter 1 (phase-A/increment) or counter 0 (direction).
A priority is as follows when used repeatedly.
Origin search settings > High-speed counter settings > Input settings
Terminal
block
label
Terminal
number
PLC Setup
Interrupt input settings on Built-in Input Tab
Page
High-speed counter 0 to 5 settings on
Built-in Input Tab Page
Origin search
settings on Pulse
Output 0/1 Tab Page
Normal
Interrupt
Quick
Use
Use
Normal input
Interrupt inputs
Quick-response
inputs
Increment
pulse input
Differential
phase ×4
or up/down
Pulse/
direction
Origin search
CIO 0
00
Normal input 0
−
−
Counter 0,
increment input
Counter 0,
phase A or
up input
Counter 0,
pulse input
−
01
Normal input 1
−
−
Counter 1,
increment input
Counter 0,
phase B or
down input
Counter 1,
pulse input
−
02
Normal input 2
Interrupt
input 2
Quick-response
input 2
Counter 2,
increment input
Counter 1,
phase A or
up input
Counter 0,
direction
−
0
3
Normal input
3
Interrupt
input
3
Quick-response
input
3
−
Counter 1,
phase B or
down input
Counter 1,
direction
Pulse 0, Origin proximity
input signal
04
Normal input 4
Interrupt
input 4
Quick-response
input 4
Counter
3
,
increment input
Counter 0,
Phase Z or
reset input
Counter 0,
reset input
−
05
Normal input 5
Interrupt
input 5
Quick-response
input 5
Counter 4,
increment input
Counter 1,
Phase Z or
reset input
Counter 1,
reset input
Pulse 1, Origin
proximity input signal
06
Normal input 6
Interrupt
input 6
Quick-response
input 6
Counter 5,
increment input
−
−
Pulse 0, Origin input
signal
07
Normal input 7
Interrupt
input 7
Quick-response
input 7
−
−
−
Pulse 1, Origin input
signal
Prohibiting Repeated Use of Input Terminal Number
Summary of Contents for SYSMAC CP Series
Page 3: ......
Page 32: ...1 Overview 1 4 CP2E CPU Unit Software User s Manual W614 ...
Page 44: ...3 CPU Unit Operation 3 8 CP2E CPU Unit Software User s Manual W614 ...
Page 116: ...6 I O Allocation 6 8 CP2E CPU Unit Software User s Manual W614 ...
Page 144: ...7 PLC Setup 7 28 CP2E CPU Unit Software User s Manual W614 ...
Page 170: ...10 Interrupts 10 14 CP2E CPU Unit Software User s Manual W614 ...
Page 200: ...11 High speed Counters 11 30 CP2E CPU Unit Software User s Manual W614 ...
Page 272: ...12 Pulse Outputs 12 72 CP2E CPU Unit Software User s Manual W614 ...
Page 278: ...13 PWM Outputs 13 6 CP2E CPU Unit Software User s Manual W614 ...
Page 460: ...18 Programming Device Operations 18 28 CP2E CPU Unit Software User s Manual W614 ...
Page 576: ...Revision 2 CP2E CPU Unit Software User s Manual W614 ...
Page 577: ......