7-21
7 PLC Setup
CP2E CPU Unit Software User’s Manual(W614)
7
-2 PLC
Setup Settings
7
7-2
-10 Pulse
Outp
ut 2 Settings
The settings are applicable to the N
3
0/40/60 CPU Units with transistor outputs.
Origin Return Settings
Name
Default
Possible settings
When setting is read by
CPU Unit
1
Speed
0 pps (disabled)
1 pps
At start of operation
:
100,000 pps
2
Acceleration Ratio (rate)
0 (disabled)
1 (pulse/4 ms)
At start of operation
:
65,5
3
5 (pulse/4 ms)
3
Deceleration rate
0 (disabled)
1 (pulse/4 ms)
At start of operation
:
65,5
3
5 (pulse/4 ms)
7-2-10 Pulse Output 2 Settings
Base Settings
Name
Default
Possible settings
When setting is read by
CPU Unit
1
Undefined Origin (operation for limit signal
turning ON)
Hold
Hold
At start of operation
Undefined
2
Limit Input Signal Operation
Search Only
Search Only
When power is turned ON
Always
3
Limit Input Signal
NC
NC
At start of operation
NO
4
Search/Return Initial Speed
0 pps
0 pps
At start of operation
:
100,000 pps
Origin Search Settings
Name
Default
Possible settings
When setting is read by
CPU Unit
1
Use define origin operation
Do not use.
Do not use.
When power is turned ON
Use.
1-1
Search Direction
CW
CW
At start of operation
CCW
1-2
Detection Method
Method 0
Method 0
At start of operation
Method 1
Method 2
1-
3
Search Operation
Inverse 1
Inverse 1
At start of operation
Inverse 2
1-4
Operation Mode
Mode 0
Mode 0
At start of operation
Mode 1
Mode 2
1-5
Origin Input Signal
NC
NC
At start of operation
NO
1-6
Proximity Input Signal
NC
NC
At start of operation
NO
Summary of Contents for SYSMAC CP Series
Page 3: ......
Page 32: ...1 Overview 1 4 CP2E CPU Unit Software User s Manual W614 ...
Page 44: ...3 CPU Unit Operation 3 8 CP2E CPU Unit Software User s Manual W614 ...
Page 116: ...6 I O Allocation 6 8 CP2E CPU Unit Software User s Manual W614 ...
Page 144: ...7 PLC Setup 7 28 CP2E CPU Unit Software User s Manual W614 ...
Page 170: ...10 Interrupts 10 14 CP2E CPU Unit Software User s Manual W614 ...
Page 200: ...11 High speed Counters 11 30 CP2E CPU Unit Software User s Manual W614 ...
Page 272: ...12 Pulse Outputs 12 72 CP2E CPU Unit Software User s Manual W614 ...
Page 278: ...13 PWM Outputs 13 6 CP2E CPU Unit Software User s Manual W614 ...
Page 460: ...18 Programming Device Operations 18 28 CP2E CPU Unit Software User s Manual W614 ...
Page 576: ...Revision 2 CP2E CPU Unit Software User s Manual W614 ...
Page 577: ......