1
8
Programming Device Operations
18-12
CP2E CPU Unit Software User’s Manual(W614)
When rungs are copied and then pasted, it is possible to automatically increment the addresses by the
specified number when pasting the rungs.
Example: When the following rung is copied, the bit addresses can be incremented by +16, and the
word address can be incremented by +10 when pasting the rung.
1
Select the above rung and then select
Address Increment Copy
from the Edit Menu.
The following dialog box will be displayed.
2
In the Offset Area set the Bit Field to 16 and the CH Field to 10 for this example.
Click the
Paste
Button.
As shown below, the addresses are automatically incremented and the rung is pasted as the
next rung.
5
Press the
Enter
Key.
This completes inputting the TIM
instruction.
Copying Rungs Using the Automatic Address Increment Function
Summary of Contents for SYSMAC CP Series
Page 3: ......
Page 32: ...1 Overview 1 4 CP2E CPU Unit Software User s Manual W614 ...
Page 44: ...3 CPU Unit Operation 3 8 CP2E CPU Unit Software User s Manual W614 ...
Page 116: ...6 I O Allocation 6 8 CP2E CPU Unit Software User s Manual W614 ...
Page 144: ...7 PLC Setup 7 28 CP2E CPU Unit Software User s Manual W614 ...
Page 170: ...10 Interrupts 10 14 CP2E CPU Unit Software User s Manual W614 ...
Page 200: ...11 High speed Counters 11 30 CP2E CPU Unit Software User s Manual W614 ...
Page 272: ...12 Pulse Outputs 12 72 CP2E CPU Unit Software User s Manual W614 ...
Page 278: ...13 PWM Outputs 13 6 CP2E CPU Unit Software User s Manual W614 ...
Page 460: ...18 Programming Device Operations 18 28 CP2E CPU Unit Software User s Manual W614 ...
Page 576: ...Revision 2 CP2E CPU Unit Software User s Manual W614 ...
Page 577: ......