15 Ethernet
15-20
CP2E CPU Unit Software User’s Manual(W614)
Note 1
Make settings using the PLC settings function in the CX-Programmer (to be included in ver-
sion 9.72 and higher).
2
For the details of IP address conversion, IP address dynamically changing and IP address
table, refer to
Section 5 Determining IP Addre
ss
e
s
in the
CS/CJ Serie
s
Ethernet Unit
s
Con-
s
truction of Network
s
Operation Manual
(Cat. No. W420).
z
FINS/TCP
Move the cursor to the
Settings
and double click. Select the Built-in Ethernet Tab. Click the
FINS/TCP Setting
button to display the FINS/TCP setup dialog.
Item
Contents
Default
FINS/UDP Port
Specify the local UDP port number to be used for the FINS communica-
tions service. The UDP port number is the number used for UDP identifi-
cation of the application layer (i.e., the FINS communications service in
this case).
• Default (9,600)
• User defined (Setting range: 1 to 65,5
3
5)
Note
Make the settings so that UDP port number does not overlap with
port number 12
3
for SNTP and port number 5
3
for DNS.
0 (9,600)
Conversion
Select any of the following as the method for finding and converting IP
addresses from FINS node addresses. (Enabled for FINS/UDP only.)
• Automatic generation (dynamic): Auto (dynamic)
• Automatic generation (static): Auto (Static)
• IP address table method: Table used
• Combined method: Mixed
Auto (dynamic)
Destination IP Address
(Change Dynamically)
Select to dynamically change the remote (destination) IP address for
FINS/UDP. To prohibit dynamic changes, deselect this box.
Checked
(Change Dynami-
cally)
IP Address Table
Set the IP address table that defines the relationship between FINS node
addresses and IP addresses.
With FINS/UDP, this is enabled only when the IP address table method or
combined method is set as the IP address conversion method.
None
Summary of Contents for SYSMAC CP Series
Page 3: ......
Page 32: ...1 Overview 1 4 CP2E CPU Unit Software User s Manual W614 ...
Page 44: ...3 CPU Unit Operation 3 8 CP2E CPU Unit Software User s Manual W614 ...
Page 116: ...6 I O Allocation 6 8 CP2E CPU Unit Software User s Manual W614 ...
Page 144: ...7 PLC Setup 7 28 CP2E CPU Unit Software User s Manual W614 ...
Page 170: ...10 Interrupts 10 14 CP2E CPU Unit Software User s Manual W614 ...
Page 200: ...11 High speed Counters 11 30 CP2E CPU Unit Software User s Manual W614 ...
Page 272: ...12 Pulse Outputs 12 72 CP2E CPU Unit Software User s Manual W614 ...
Page 278: ...13 PWM Outputs 13 6 CP2E CPU Unit Software User s Manual W614 ...
Page 460: ...18 Programming Device Operations 18 28 CP2E CPU Unit Software User s Manual W614 ...
Page 576: ...Revision 2 CP2E CPU Unit Software User s Manual W614 ...
Page 577: ......