System Maintenance
Section 3-10
3-10 System Maintenance
In order to facilitate maintenance, the NT11S is provided with functions including
the I/O check function and a function for confirming the NT11S settings.
3-10-1 I/O Check
The I/O check function checks whether the inputs and outputs for the following
items are normal.
- LEDs
- LCD
- Key input
- Communication interface
LED check
Carry out the LED check by performing the following operations, starting from the
system menu.
Select “Maintenance Mode”
with the
key, then press “EN-
TER”.
Select “I/O Check” with the
key, then press “ENTER”.
Select “LED Check” with the
key, then press “ENTER”.
The “RUN” LED on the panel of the NT11S will blink.
S
To quit the LED check, press any two of the function keys simultaneously.