84
Bar Graphs
Section 4-5
S
Setting the 100 % value and % display
Set a value which corresponds to 100 % for the “100 % value”. The available
value range is “0 to 99999999” (max. eight digits). For the “% display”, whether
or not the proportion (percentage) of the reference numeral memory table value
to the “100 % value” is displayed in a numeral can be selected. The display value
is calculated as follows:
“% display” value = Numeral memory table value
÷
“100 % value” x 100
For the font and attributes used for the numeral display, refer to “Numerals which
can be displayed” (page 82).
S
Display of negative values (less than 0%)
The bar graph is displayed in the range of 0 % to 100 %. The end of the bar graph
indicates 0 %. Values below 0 % are indicated as 0 %.
% display
0 %
100 %
60 %
S
Display method when the percentage value is in the range 100% to 999%
% display
0 %
100 %
999 %
Graph width: 8 dots
«
1-dot-wide space
S
Display method when the percentage value is 1000% or greater
The bar graph will be displayed the same as (2) above.
The percentage value is indicated by three asterisks:
***%