36
Connection to a PC by the Host Link (RS-422A Type)
Section 2-5
[Setting the rear switches]
C200H-LK201(-V1)
O
N
1
2
3
4
S
1-to-1/1-to-N selection (DIP switch)
Set No. 3 to “ON”.
S
CTS selection (selector switch)
Set this always to “0V” (ON).
CTS
selector
switch
External
«
0V (ON)
C200H-LK202(-V1)
This type has an RS-422A connector.
CTS
selector
switch
External
«
0V (ON)
1-to-1
protocol
(ON)
«
1-to-N
protocol
(OFF)
S
Terminator setting (selector switch)
Set this switch to “ON”.
Note: Set the link adapter to “ON” also.
S
1-to-1/1-to-N protocol selection (selector switch)
Set this switch to “1-to-N (OFF)”