Method for Making the Cable for Connection to the PC
Appendix D
APPENDIX D
Method for Making the Cable for Connection to the PC
Explained below is the method for making the cable that connects the NT11S and the PC/Host.
Connect the wires to the connectors in accordance with the connector specification for each unit.
Making the Cable for Connection to the PC (RS-232C Type)
Parts Required
Two connectors, two connector covers and one cable are required to make up a connecting cable. One connector
and one connector cover is supplied with most PCs.
Name
Model
Delivered with
Remarks
Connector
XM2A-0901
C series CQM1
9-pin, manufactured by OMRON
C
Connector
XM2A-2501
C200H-LK201
25-pin, manufactured by OMRON
P
C
Connector
cover
XM2S-0911
C series CQM1
9-pin, manufactured by OMRON
Connector
cover
XM2S-2511
C200H-LK201
25-pin, manufactured by OMRON
1S
Connector
XM2A-0901
—
9-pin, manufactured by OMRON
N
T
11
S
Connector
cover
XM2S-0911
—
9-pin, manufactured by OMRON
When connecting the NT11S to an OMRON PLC C
jj
H , the connector and the connector cover must be prepared
separately since they are not supplied with the C
jj
H.
The connector provided in the CPU unit of the C
jj
H is a 9-pin connector. For the connection, the following con-
nector and connector hood should be prepared.
S
Connnector:
XM2A-0901 (9-pin type, OMRON)
S
Connector cover: XM2S-0911 (9-pin type, OMRON)
Prepare the cable recommended by OMRON.
The recommended cables are indicated in the following table.
Name
Type
Remark
Cable
AWG28
¢
5P
IFVV-SB
Multiconductor shielded cable (FUJIKURA, Ltd.)
Cable
CO-MA-VV-SB
5P
¢
28AWG
Multiconductor shielded cable (HITACHI Cable, Ltd.)
Summary of Contents for NT11S
Page 1: ...Cat No V029 E1 2 NT11S Programmable Terminal OPERATION MANUAL ...
Page 3: ...i ...
Page 4: ...ii ...
Page 5: ...iii NT series Programmable Terminal Operation Manual Produced June 1997 ...
Page 6: ...iv ...
Page 8: ...vi ...
Page 32: ...16 ...
Page 56: ...40 ...
Page 86: ...70 ...
Page 146: ...130 ...