20
Description of Parts and Settings
Section 2-1
2-1-2
DIP Switch Settings
Set the NT11S operation status with the DIP switches located in the bottom right
corner on the rear side of the body.
Switch #
Function
SW2-1
RS-422A terminal resistor connection
SW2-1
ON
Terminal resistor used
[OFF]
Terminal resistor not used
SW2-2
Screen data forced initialize effective/ineffective
SW2-2
ON
The NT11S will start in a special RUN mode in which the screen
data memory is initialized. When it is started, the memory initial-
ization menu will be displayed. For the initialization procedure,
refer to Section 3-4 Initializing Memory (page 48).
[OFF]
The NT11S will start in normal RUN mode.
SW2-3
Screen display language mode
SW2-3
ON
[OFF]
Messages are displayed in English.
SW2-4
Switching to the System Menu enabled/disabled
SW2-4
ON
The System Menu cannot be displayed. If an error occurs during
a start-up, the System Menu will be automatically displayed.
However, “RUN Mode” cannot be entered.
[OFF]
The System Menu can be displayed.
SW2-5
Not used.
SW2-6
System program erase
SW2-6
ON
The menu for deleting the system program is displayed on strat-up.
[OFF]
Start-up proceeds as normal.
[ ] indicates factory setting.
Summary of Contents for NT11S
Page 1: ...Cat No V029 E1 2 NT11S Programmable Terminal OPERATION MANUAL ...
Page 3: ...i ...
Page 4: ...ii ...
Page 5: ...iii NT series Programmable Terminal Operation Manual Produced June 1997 ...
Page 6: ...iv ...
Page 8: ...vi ...
Page 32: ...16 ...
Page 56: ...40 ...
Page 86: ...70 ...
Page 146: ...130 ...