In this example, let’s set the parameters as follows:
“Security”
“2” (all parameters in modes other than the setup
mode are protected)
“Key protect”
“1” (Auto/manual key operation cannot be
switched)
(1) Press the
RUN/RST
and
keys simultaneously for 1 second mini-
mum. The controller enters the protect mode. In the protect mode,
the top parameter in the protect mode “security” is displayed.
Default is “1”.
(2) Press the
key to change the parameter setting to “2”.
(3) Press the
key to switch to the “key protect” parameter.
(4) Press the
key to change the parameter setting to “1”.
(5) Press the
and
RUN/RST
keys simultaneously for 1 second mini-
mum. The display changes to the “PV/Present SP monitor” param-
eter (level 0 mode).
Setting Example
RUN/RST
RUN/RST
1 second min.
1 second min.