Ribbon Cable
NOTE: This is the main cable for all
electronics.
Tools Required
Tape
3. Disconnect ribbon cable.
4. Remove ribbon cable from clips.
5. Remove cable from clips, then tape new cable to end of old cable and
pull it up through the electronic tube at this point.
Note: Bottom view shown.
Be gentle pulling cable through tube!
Additional Installation Notes:
1. Make sure all wires are secured in cable clips on frame and out of path of timing
belts.
2. Make sure ribbon cable is fastened securely to board connector in step 3 above.
3. Before installing covers, it’s a good idea to test the display to make sure everything
is working correctly.
42073 Ribbon Cable 5-01-05
62
The TRS 4000 is very heavy; it weighs
205 lbs (93 kg). To avoid injury, or
damage to the product, always obtain
assistance to move this product. Use
proper lifting technique.
!
CAUTION
1. Remove covers.
See
Cover Removal
instruction.
2. Remove display.
(See
Display Removal
instruction.)
Keep old ribbon cable
hanging out of top end of electronic tube for pulling new cable up through
tube!
6. To install remainder of lower portion of ribbon cable, do above steps in
reverse order. No photo.
Make sure newly installed cable is out
of way of pivot casting boot during
operation.