TRS 4000
[email protected] - (800) 322-4434 - (734) 769-3939 x 5
[email protected] - (800) 322-4434
EC Magnet
NOTE: Units with S/N > 412485 have 3 screws and no separate bracket to attach
the magnet assembly, while those with lower S/Ns have 2 screws and a separate
bracket. This instruction applies to both but a lower S/N unit is shown.
Tools Required
Phillips screwdriver (long)
1. Remove top and left side cover.
See
Cover Removal
instruction.
2. Remove 2 (or 3) screws holding
magnet assembly.
3. On older models, remove screws
holding this separate bracket to EC
Magnet bracket (shown). On newer
models there is no separate bracket.
Insert screwdriver as shown. Lower
magnet assembly downward and out.
4. To install, do above steps in re-
verse order. Set magnet and disk
gap alignment per instructions
below.
5. Ride test and make sure disk
does not hit magnets in all 10 loads
before installing covers.
For Gap Alignment between magnet
and disk:
~1/8" gap this side
~1/16" gap this side
Ride test to make sure disk does not
hit magnets in all 10 loads.
42029 EC Magnet 9-10-00