Pivot Shaft Alignment
NOTE: This instruction only applies to units with S/N < 411609 and will help
prevent shaft from sliding axially in bearings. Later models have a grooved shaft.
Tools Required
5/32" hex key
Loctite 290 (wicking)
Rawhide hammer
Safety glasses
2. Remove caps, loosen and remove
set screws from both collars.
3. Tap shaft with hammer until right
end of shaft aligns with end of right
collar (shown).
Note: Right side shown.
4. With set screws removed from
both sides, pour a few drops of 290
Loctite down into set screw holes.
Tighten set screws back down and
replace caps.
42063 Pivot Shaft Alignment 5-1-05
33
1. Rotate right arm forward to work on right side, left arm forward to work
on left side.
To avoid injury, wear safety glasses.
!
CAUTION
To avoid injury and prevent adverse
health effects, use Loctite in
accordance with the manufacturer’s
material safety data sheets, including
the use of safety glasses and
impermeable gloves. Material safety
data sheets are available via the
internet at
www.loctite.com
or by
calling Henkel Corporation at (800) 562-
8483.
!
CAUTION