TRS 4000
[email protected] - (800) 322-4434 - (734) 769-3939 x 5
[email protected] - (800) 322-4434
42019 DC Power Cable 5-01-05
DC Power Cable
5. To install, plug power cable into
board.
Snap connector end of power cable
into connector pins on PCB board.
Make sure connector is installed with
cable wires exiting from the top of
connector and that connector is
securely snapped in place.
6. Prepare power cable.
Remove nut and lockwasher from the
end of the jack. Push jack through the
hole in the frame on the inside of the
cover (as shown).
Now from the outside (not shown),
place lockwasher and nut onto end of
jack. Tighten nut with 11mm socket
wrench while holding jack from inside.
Jack hole Power cable jack
7. Route wiring through clip(s).
Loop extra cable back and forth and
insert into a clip to keep it out of the
way of moving parts.
Make sure power cable is out of the
way of the ribbed timing belt.
8. Turn NuStep upright and test
power with AC adapter.
59