Hall Effect Sensor
42055A Hall Effect Sensor 5-01-05
7. To install, do above steps in reverse order. Set gap alignment.
To Set Gap Alignment:
Additional Installation Notes:
1. Make sure all wires are secured in cable
clips on frame and out of path of timing
belts.
2. Make sure wire exits from top of connector
when installing into PCB connector in step 3
above.
3. Before installing covers, it’s a good idea to
test the sensor to make sure everything is
working correctly.
Set gap at 1/8" – 3/16" between sensor
and magnet on pivot disk.