Load Lever
Tools Required
¾” socket, ratchet and extension
Hammer
Safety glasses
2. Loosen load lever nut until just a
few threads are holding nut on.
3. Tap gently on nut to disengage
load lever, then remove nut
completely.
4. Remove load lever.
5. Reinstall load lever and tighten
nut just enough to draw roll pin into
groove and remove play. Do not
overtighten nut.
6. Check operation of load lever and “Workload” on display. Install covers.
No photo.
42057 Load Lever 5-01-05
56
1. Remove covers.
See
Cover Removal
instruction.
To avoid injury, wear safety glasses.
!