EC Ball Plunger Replacement / Adjustment
Tools Required
Flat head screwdriver
1. Remove covers.
See
Cover Removal
instruction.
2. Place workload lever in position 4.
3. NOTE: If you are just adjusting
ball plunger GOTO Step 4. If
replacing, remove old one and
replace with new one.
4. Tighten ball plunger until ball just
seats into each hole on plate.
NOTE: Move workload lever back and
forth and then adjust ball plunger.
If workload lever is too tight (lever
moves hard, and body of ball plunger
scrapes plate), loosen ball plunger by
turning a little to the left.
If workload lever is too loose (there is a
little “play” in each position), tighten ball
plunger by turning a little to the right.
The right “feel” is achieved when the
workload lever hits each position, but is
not too hard to move or has excessive
“play.”
5. Test that all 10 Workload Levels
show on display. No photo.
6. Install covers. No photo.