Workload Level PCB
Tools Required
Parts Required
Scratch awl
(4) 1/8" diameter by 5/16" length pop rivets
Hammer
Safety glasses
Pop rivet gun
3. Disconnect wires from back of
PCB.
4. From outside of frame, pound out
rivets using scratch awl & hammer.
5. Remove PCB and insulator board
from frame.
No photo.
6. Carefully install new PCB and
insulator board between wiper and
frame using pop rivets. (see
reference photo below before
proceeding).
8. Test all electronics before
installing covers.
7. Reconnect wires shown in Step 3.
Reference Photo:
Workload PCB
NOTE: EC Plunger shown removed
from frame for clarity. It is not
necessary to remove plunger to install
PCB, but you must be careful when
installing PCB.
Insulator board Wiper
42111 Workload Level PCB 5-01-05
57
1. Remove covers.
See
Cover
Removal
instruction.
2. Put workload lever in load 1.
To avoid injury, wear safety glasses.
!