Factory Service Mode Test Procedures
255
TROUBLESHOO
TING
2.
THV Tune Up
This mode is used when transfer voltage needs to be adjusted due to the errors caused such as transfer failure
on the media. The adjustment is to change the transfer voltage, subject to the media to be used, against the
reference value 0 (zero) in the range between the step -4 and +4.
a.
Press Select key after selecting NVM TUNE UP.
b. After selecting THV TUNE UP Code 2, press Select key.
c.
After selecting the media to be tuned up, press Select key. (i.e. PPC)
d. Tune Up value can be adjusted within 8 steps between the step -4 and +4.
e.
After selecting a given number, press Select key.
f.
Press the Clear key to wrap up the tune-up work for PPC.
g. Repeat the step 3 through 5 for other media such as OHP or Label.
h. Press the Clear key to wrap up the tune-up work.
3.
DBV Tune Up
This mode is used when image optical density needs to be adjusted. Adjustment is to adjust the developer
bias voltage against the reference value 0 (zero) in the range between the step -4 and +4.
a.
Press Select key after selecting NVM TUNE UP.
b. After selecting DBV TUNE UP Code 3, press Select key.
c.
After selecting the color to be tuned up, press Select key. (i.e. Magenta)
d. Tune Up value can be adjusted within 8 steps between the step -4 and +4.
e.
After selecting a given number, press Select key.
f.
Press the Clear key to wrap up the tune-up work for Magenta.
g. Repeat the steps c through e for each color.
h. Press the Clear key to wrap up the DBV tune-up work.
4.
CBV Tune Up
This mode is used when the image defects attributing to transfer drum need to be improved. Adjustment is to
adjust the drum cleaner bias voltage against the reference value 0 (zero) in the range between the step -4 and
+4.
a.
Press Select key after selecting NVM TUNE UP.
b. After selecting CBV TUNE UP Code 5, press Select key.
c.
Tune Up value can be adjusted within 8 steps between the step -4 and +4.
d. After selecting a given number, press Select key.
e.
Press the Clear key to wrap up the tune-up work for CBV.
5.
FBV Tune Up
This mode is used when the image defects attributing to transfer drum need to be improved. Adjustment is to
adjust the drum cleaner bias voltage against the reference value 0 (zero) in the range between the step -4 and
+4.
a.
Press Select key after selecting NVM TUNE UP.
a.
After selecting FBV TUNE UP Code 6, press Select key.
a.
Tune Up value can be adjusted within 8 steps between the step -4 and +4.
a.
After selecting a given number, press Select key.
a.
Press the Clear key to wrap up the tune-up work for FBV.
46 NVRAM Initial
This mode can initialize (data clear) all the data of NVRAM on MCTL PWB.
1.
Select YES if NVRAM should be executed. If not, select NO.
2.
Press Select key so that RAM INITIAL will be executed. (All the data will be cleared.)
3.
Following modes shall be executed to set the RAM data.
Summary of Contents for Super Script 4400
Page 1: ...NEC SuperScript 4400 4400N Maintenance Guide 18 September 1998 Part Number 703 A0240 001 ...
Page 3: ...i SuperScript 4400 Maintenance Guide ...
Page 61: ...52 SuperScript 4400 Maintenance Guide ...
Page 71: ...62 SuperScript 4400 Maintenance Guide ...
Page 125: ...116 SuperScript 4400 Maintenance Guide ...
Page 189: ...180 SuperScript 4400 Maintenance Guide Toner Sensor TPD Toner Sensor TTR Fram Ass y ...
Page 193: ...184 SuperScript 4400 Maintenance Guide Stay A Ass y Transfer Drum ...
Page 203: ...194 SuperScript 4400 Maintenance Guide Stay A Ass y ...
Page 267: ...258 SuperScript 4400 Maintenance Guide ...
Page 273: ...264 SuperScript 4400 Maintenance Guide ...
Page 287: ...XIV SuperScript 4400 Maintenance Guide F G H I J ...
Page 289: ...XVI SuperScript 4400 Maintenance Guide ...
Page 293: ...ii Superscript 4200N and 4400 Series Maintenance Guide Addendum ...
Page 295: ...iv Superscript 4200N and 4400 Series Maintenance Guide Addendum ...
Page 302: ...7 ...
Page 314: ...19 NOTES ...
Page 315: ...20 Superscript 4200N and 4400 Series Maintenance Guide Addendum ...
Page 316: ......