• When an internal station-to-station call is made to a virtual extension, the name and number of the
calling party does not appear in the display of the station the virtual extension resides on until the
call is answered.
• A door box cannot ring a virtual extension.
• If a user dials a number not programmed in ARS, PRG 26-01-03 determines if the system should
route over the trunk group settings defined in PRG 21-02 or play an error tone.
• When using ARS Class of Service, with PRG 26-01-03 set to (1) "Play Warning Tone", Any trunk
pointed or transferred to a virtual that is Call Forward Off-Premise will not complete. For a virtual to
Call Forward Off-Premise, PRG 26-01-03 must be set to "Route to trunk group" and the call will
follow the trunk group settings of the trunk, assigned in PRG 21-03.
• When using ARS Class of Service, with PRG 26-01-03 set to (1) "Play Warning Tone" or transferred
to a virtual that is call forwarded off premise will always follow ARS Class 1 routing properties.
• Version 2.0, or higher, software supports distinctive ring tones for external calls or intercom calls
from specified extensions.
• Ringtone mode for incoming to Virtual Extension (PRG 20-04-05 is On) is followed by PRG
22-03-01 and PRG 15-02-02 for External calls and PRG 15-08-01 and PRG 15-02-02 for Intercom
call ringing. (Version 2.0 or higher)
Default Settings
Not Assigned
System Availability
Terminals
All Multiline Terminals
Required Component(s)
None
Related Features
Call Waiting/Camp-On
Call Arrival (CAR) Keys
Secondary Incoming Extension
Guide to Feature Programming
The programs listed below indicate the most commonly used programs required for this feature. The
programs are listed in the order that the installer should follow. Refer to the PCPro wizards for further
detailed programming.
• When a * is listed next to the Program Number it indicates a program that
MUST
be set (from a
default state) for this feature to be enabled.
ISSUE 2.0
SL1100
Features and Specifications Manual
1-773
V
Summary of Contents for SL1100
Page 2: ......
Page 3: ...Features and Specifications Manual A50 031169 003 NA ISSUE 2 0 ...
Page 171: ...5 Press Speaker key to hang up ISSUE 2 0 SL1100 Features and Specifications Manual 1 159 C ...
Page 218: ...2 Dial 724 SL1100 ISSUE 2 0 1 206 Dial Pad Confirmation Tone D ...
Page 741: ... Direct Inward Dialing DID ISSUE 2 0 SL1100 Features and Specifications Manual 1 729 T ...
Page 856: ...MEMO SL1100 ISSUE 2 0 2 26 Codes Tables ...
Page 862: ...MEMO SL1100 ISSUE 2 0 3 6 Features Availability by Software Revision ...
Page 863: ...MEMO ISSUE 2 0 SL1100 Features and Specifications Manual 3 7 ...
Page 864: ...Features and Specifications Manual NEC Corporation ISSUE 2 0 ...