![background image](http://html.mh-extra.com/html/nec/express5800-a1080a/express5800-a1080a_user-manual_251254641.webp)
Operation and Maintenance
641
CPU Test
(1) Outline
Cache Test
This test writes and reads memory for the test area, and the results are compared.
Floating point arithmetic test
This test executes floating point arithmetic instruction.
(2) Message
1. Standard message
Message Content
Start CPU test. (thread : xxx
cache size : yyy)
Test is started.
“xxx”
is the number of threads.
“yyy”
is the
cache size.
Successfully completed the CPU test.
Test ended normally.
Halted the CPU test due to requests.
CPU test is stopped by halt requests.
2. Error message
Message Content
Terminated CPU Cache test due to errors.
Failing Address Good Bad CPU Number
------------------- ------ ----- ----------------
xxx
yyy zzz aaa
Error is detected on the cache test.
Error address, expected value, result value and
CPU number are displayed.
Terminated Floating Point Arithmetic Test
due to error.
compare failed.
CPU Number : xxxxx
Good :
yyyyy
Bad :
zzzzz
Error is detected on the floating point arithmetic
test.
CPU number, expected value file and result
value file are displayed.
Summary of Contents for Express5800/A1080a
Page 87: ...87 Memo ...
Page 292: ...Hardware 292 3 BIOS Menu screen is displayed ...
Page 302: ...Hardware 302 Note 1 Enable is set only for slot 1 and slot 14 at factory shipment ...
Page 351: ...Hardware 351 3 BIOS will start Select Save Exit then press Enter ...
Page 442: ...Hardware 442 5 6 ...
Page 473: ...Hardware 473 Screen for changing keyboard layout in Java Console ...
Page 554: ...Hardware 554 Memo ...
Page 565: ...Software 565 Memo ...
Page 668: ...Operation and Maintenance 668 Memo ...
Page 696: ...XXVIII Memo ...