Hardware
191
Preparation for Mounting/Unmounting
Prepare for mounting/unmounting parts by following the procedure below.
1. Set
to
the
maintenance
mode (refer to “Set Maint Mode”).
2. Shut down OS of the server to be replaced and turn OFF the power.
Step 2 is omitted in the following case.
· In
A1080a-S /A1080a-D/A1080a-E
, the operation in step 2 is not performed when replacing a
hard disk configured in RAID other than RAID0, a fan module, or a power supply unit/power
cable in the power redundant configuration.
3. Secure enough space on the front, rear, right, and left side, and top of the server.
IMPORTANT:
It is required to turn off the power of the server when
adding/replacing parts, except for online replacement.
IMPORTANT:
A hard disk configured in RAID other than RAID0, a fan module, or
a power supply unit/power cable in the power redundant
configuration can be replaced online.
IMPORTANT:
In A1080a-D model, turn OFF the DC power of both servers when
replacing DVD drive device.
In all models, turn OFF the DC power of the server when replacing
a hard disk configuring RAID0
Summary of Contents for Express5800/A1080a
Page 87: ...87 Memo ...
Page 292: ...Hardware 292 3 BIOS Menu screen is displayed ...
Page 302: ...Hardware 302 Note 1 Enable is set only for slot 1 and slot 14 at factory shipment ...
Page 351: ...Hardware 351 3 BIOS will start Select Save Exit then press Enter ...
Page 442: ...Hardware 442 5 6 ...
Page 473: ...Hardware 473 Screen for changing keyboard layout in Java Console ...
Page 554: ...Hardware 554 Memo ...
Page 565: ...Software 565 Memo ...
Page 668: ...Operation and Maintenance 668 Memo ...
Page 696: ...XXVIII Memo ...