Hardware
338
RAID5
In RAID5, data is distributed to HDDs by striping and, at the same time, the parity (redundant
data)
is distributed to the HDDs. This mode is called "striping with distributed parity".
Each of stripe x, stripe x+1, and parity (x, x+1) created from stripe x and stripe x+1 is written onto
a
specific HDD. Accordingly, the total capacity assigned to the parity is just the same as the
capacity
of a single HDD. If any one of the HDDs configuring a logical drive is defected, data is
still
available with no problems.
RAID6
RAID 6 extends RAID 5 by adding an additional parity block (Q) created by different calculation
method such as weighting by some factor, and thus uses block-level striping with two parity
blocks distributed across all the member disks. This mode is called "striping with duplex and
distributed parity". Accordingly, the total capacity assigned to the parity is just the same as the
capacity of two HDDs. If two of the HDDs configuring a logical drive are defective, data is still
available.
HDD 1
RAID Controller
HDD 2
HDD 3
Stripe 1
Stripe 4
Stripe 2
Pality P(3,4)
Pality P(1,2)
Pality Q(3,4)
Pality P(5,6)
Pality Q(5,6)
Stripe 5
HDD 4
Pality Q(1,2)
Stripe 3
Stripe 6
Pality Q(7,8)
Stripe 7
Stripe 8
Pality P(7,8)
HDD 1
RAID Controller
HDD 2
HDD 3
Stripe 1
Stripe 4
Stripe 2
Pality(3,4)
Pality(1,2)
Stripe 3
Pality(5,6)
Stripe 5
Stripe 6
Summary of Contents for Express5800/A1080a
Page 87: ...87 Memo ...
Page 292: ...Hardware 292 3 BIOS Menu screen is displayed ...
Page 302: ...Hardware 302 Note 1 Enable is set only for slot 1 and slot 14 at factory shipment ...
Page 351: ...Hardware 351 3 BIOS will start Select Save Exit then press Enter ...
Page 442: ...Hardware 442 5 6 ...
Page 473: ...Hardware 473 Screen for changing keyboard layout in Java Console ...
Page 554: ...Hardware 554 Memo ...
Page 565: ...Software 565 Memo ...
Page 668: ...Operation and Maintenance 668 Memo ...
Page 696: ...XXVIII Memo ...