Hardware
200
5. Mount the power supply unit with opposite steps of steps 1-4. Confirm that it is inserted
completely and locked till it clicks.
6. Install the power code and fix the cable with the repeat ties for preventing from falling off.
7. Clear the maintenance mode set in step 2.
NOTE:
When the power supply unit of the server operating in power
redundant configuration is replaced while the power is ON
(Online), the Status LED lights in green after the power supply unit
is mounted when the power code is connected.
On the other hand, when the power supply unit operating in
non-power redundant configuration is replaced while the DC
power is OFF (Offline), the Status LED blinks in green after the
power code is connected. And it lights when the DC power is
turned ON.