Operation and Maintenance
600
(5) Read the information on the
Monitoring Event Log
screen as necessary since information
listed here needs to be collected in the next procedure.
To collect event log data, right-click on the
Event Log
screen and select
“Select All (A)”
.
Then, right-click and select
“Copy (C)”
. Paste the data on the text editor. Up to 100 event
logs can be displayed at one time. Select a full-screen mode when there are 100 or more
event logs.
(6) Repeat steps from 1 to 5 above for all WEB Consoles that need to be confirmed.
4. BID
(
Build
In Diagnostic
)
Screen to show the failure on the suspected part
<
Description
>
BID : *********** Analysis Result *********************************************
1
BID : ----------- Fault Analysis Result ---------------------------------------
No. 1 DIMM [PMM0/DIMM000 ] 90%
No. 2 PMM [PMM0 ] 10%
2
BID : ----------- Fault Analysis Result (Component) ---------------------------
No. 1 ----- DIMM [PMM0/DIMM000 ] 90%
No. 2 ----- PMM [PMM0 ] 10%
3
BID : ----------- Error Information -------------------------------------------
PROC100 Memory single-bit ECC error occurred.
CELL1/PMM0/DIMM000 ADDRESS=0x0012_77FE_AF80 ECC_INFO=0x8890
Main memory DIMM patrol read data error occurred.
DIMM error information. SDRAM=No.D14, Signal(s)=DQ47
4
BID : ----------- Register Dump -----------------------------------------------
PROC100 EVENT=0004 SSB=04 AT0=000000_00000000 AT1=000004_00000000 TRN=0
BID : *************************************************************************
Replacement FRU/CRU:
The suspected failure percentage of the part is displayed based on the number of units to be
replaced when a failure occurs. The higher the suspected failure percentage for a part is, the
higher the possibility that the part is the cause of failure. However, the sum of the percentage
may not be 100, since after the decimal point is rounded off. The name of the part identified in
No.1 of the BID is displayed in
View Faults
of the LCD.
BID : ----------- Fault Analysis Result -----------------------------
No. 1 DIMM [PMM0/DIMM000 ] 90%
No. 2 PMM [PMM0 ] 10%
Whether to replace a part is determined here.
CRU
:
Customer Replaceable Unit
FRU
:
Field Replaceable Unit
Part name
Location
Suspected failure percentage
Summary of Contents for Express5800/A1080a
Page 87: ...87 Memo ...
Page 292: ...Hardware 292 3 BIOS Menu screen is displayed ...
Page 302: ...Hardware 302 Note 1 Enable is set only for slot 1 and slot 14 at factory shipment ...
Page 351: ...Hardware 351 3 BIOS will start Select Save Exit then press Enter ...
Page 442: ...Hardware 442 5 6 ...
Page 473: ...Hardware 473 Screen for changing keyboard layout in Java Console ...
Page 554: ...Hardware 554 Memo ...
Page 565: ...Software 565 Memo ...
Page 668: ...Operation and Maintenance 668 Memo ...
Page 696: ...XXVIII Memo ...