![background image](http://html.mh-extra.com/html/nec/express5800-a1080a/express5800-a1080a_user-manual_251254633.webp)
Operation and Maintenance
633
Checking Test Status
Use
<stat>
command to check the progress of the test. To check the detailed status for each
test, use
<statv>
command. This command shows the number of executed times and
progressing status of each time for each test.
The following is an example of screen using the commands.
•
One of the following three statuses is displayed in
“Status.”
This is the status of TeDoLi
itself.
Idle status
: Status before starting the test. Or the status after
the completion of test.
Executing status
: Status that the test is being executed.
Waiting for
Termination status
: Status that waiting for the completion of the test.
•
Elapsed time of the test being executed (elapsed time from entering
<exec>
command) is
displayed in
“Time.”
The time is updated until all the tests are completed.
•
“Total of tests”
shows the total number of tests. Test types are sorted as follows
depending on the executed test results.
Pass:
: Number of tests ended normally
Failure
: Number of tests ended with error
Warning : Number of tests ended with warning (# This is an information expanded
in the future and is not supported as of yet).
•
There are two procedures to specify the test with
<statv>
command.
Specifying “Test device number”
: Specifies the test device number in
“Num”
row.
Specifying
<all>
: Specifies all the devices.
•
“Test Count”
shows the number of executed test. This item shows
“1”
immediately after
starting the test.
•
“Progress”
shows the degrees of progress of the test in the test round. This is not the
degree of progress for the entire rounds.
TeDoLi> stat
Status : Executing
Time : 000:00:44
Total of tests : 15
Running : 15
Pass : 0
Failure : 0
Warning : 0
TeDoLi> statv 14
----------------------
BM/MB/PCI8/Port1(eth0)
----------------------
Test Count : 74
Progress : 49%
Summary of Contents for Express5800/A1080a
Page 87: ...87 Memo ...
Page 292: ...Hardware 292 3 BIOS Menu screen is displayed ...
Page 302: ...Hardware 302 Note 1 Enable is set only for slot 1 and slot 14 at factory shipment ...
Page 351: ...Hardware 351 3 BIOS will start Select Save Exit then press Enter ...
Page 442: ...Hardware 442 5 6 ...
Page 473: ...Hardware 473 Screen for changing keyboard layout in Java Console ...
Page 554: ...Hardware 554 Memo ...
Page 565: ...Software 565 Memo ...
Page 668: ...Operation and Maintenance 668 Memo ...