Section 75
00-02-0878
2013-03-07
- 171 -
Events
Description
Notes
Events
Mode shift deactivated
AMF (Automatic Mains Failure).
3-phase system
AC configuration.
Split L1L3-phase system
Split L1L2-phase system
Single phase system
Test application selected with output cmd enabled
Emulation with engine and breaker relay
reaction.
Test application selected with output cmd disabled
Emulation without engine and breaker relay
reactions.
BB Parameter set 1 used
Nominal busbar settings 1 and 2.
BB Parameter set 2 used
60 Hz system
The event becomes true if the nominal
frequency is higher than 55 Hz.
Logic
Not used
-
TRUE
“Always”.
FALSE
“Never”.
Command
Timers
Cmd timer 01 active
The command timers will operate in pairs of
two to activate and deactivate a flop-flop
function.
Cmd timer 02 active
Cmd timer 03 active
Cmd timer 04 active
Any Cmd timers active
Can
Inputs
CAN inputs 01-16 active (expansion I/O)
The CAN inputs are handled as binary
inputs
Inputs
Binary input activated (digital input or external I/O)
The number of binary inputs selectable is
hardware option dependent. The number
indicates the terminal number for the input
in question.
Emergency stop
Emergency stop input activated (note that
this is normal state for emer.).
Modes
Island
Island is one or several generators running
in an island NOT connected to mains grid.
AMF
Automatic mains failure.
Peak shaving
Peak shaving cuts the peak of the mains
consumption by paralleling the generator to
the mains.
Fixed power
Mains grid parallel fixed generator power.
Mains power export
Export of power to the mains grid.
Load takeover
Load is transferred from mains to generator,
and mains is disconnected.
Auto mode
Test mode
Manual mode
Block mode
Summary of Contents for EMS-GC10
Page 1: ...00 02 0878 Section 75 2013 03 07 GensetControllerUnit ModelEMS GC10 Operator sManual ...
Page 14: ...Section 75 00 02 0878 2013 03 07 8 Menu Structure Diagram ...
Page 33: ...Section 75 00 02 0878 2013 03 07 27 MB Open Sequence ...
Page 34: ...Section 75 00 02 0878 2013 03 07 28 GB Open Sequence ...
Page 35: ...Section 75 00 02 0878 2013 03 07 29 Stop Sequence ...
Page 36: ...Section 75 00 02 0878 2013 03 07 30 Start Sequence ...
Page 37: ...Section 75 00 02 0878 2013 03 07 31 MB Close Sequence ...
Page 38: ...Section 75 00 02 0878 2013 03 07 32 GB Close Sequence ...
Page 39: ...Section 75 00 02 0878 2013 03 07 33 Load Takeover LTO ...
Page 40: ...Section 75 00 02 0878 2013 03 07 34 Island Operation ...
Page 41: ...Section 75 00 02 0878 2013 03 07 35 Automatic Mains Failure AMF ...
Page 42: ...Section 75 00 02 0878 2013 03 07 36 Test Sequence ...
Page 48: ...Section 75 00 02 0878 2013 03 07 42 Stop Sequence The drawings illustrate the stop sequence ...
Page 74: ...Section 75 00 02 0878 2013 03 07 68 Start ...