![MPE XR III series Operator'S Manual Download Page 76](http://html1.mh-extra.com/html/mpe/xr-iii-series/xr-iii-series_operators-manual_1843049076.webp)
Returned Parameters: 0 | 1
Related Commands: None
4.3.10.3 CONT:EXT
This command enables or disables the external inputs for start, stop, arm, and clear.
The query command, CONT:EXT?, returns the status of external control.
Command Syntax:
[CONFigure]:CONTrol:EXTernal <bool>
Parameters:
0 | OFF | 1 | ON
Examples:
CONF:CONT:EXT ON
CONT:EXT 0
Query Syntax:
[CONFigure]:CONTrol:EXTernal?
Returned Parameters: 0 | 1
Related Commands: None
4.3.10.4 INTE
This command enables or disables the external interlock feature. Interlock, described in Section
3.6, is used for applications where the power supply needs to be disabled under external
conditions.
The query command, INTE? returns the status of external interlock.
Command Syntax:
[CONFigure]:INTErlock <bool>
Parameters:
0 | OFF | 1 | ON
Examples:
CONF:INTE ON
INTE 0
Query Syntax:
[CONFigure]:INTErlock?
Returned Parameters: 0 | 1
Related Commands: None
4.3.10.5 CONF:SETPT
64
Summary of Contents for XR III series
Page 1: ...OPERATING AND SERVICE MANUAL XR SERIES III DC POWER SUPPLIES...
Page 2: ......
Page 3: ...MAGNA POWER ELECTRONICS INC 39 ROYAL ROAD FLEMINGTON NJ 08822 February 20 2012...
Page 4: ......
Page 88: ...Figure 4 1 Status Byte Generation Figure 4 2 ESE and ESR Generation 76...
Page 95: ...IEEE Standard CLS ESR ESE STB SRE IDN SAV RCL RST Notes 1 C command Q query 83...
Page 97: ...Figure 5 1 Configuration setup Figure 5 2 GPIB communications setup 85...
Page 99: ...Figure 5 4 Virtual Control Panel Figure 5 5 Command Panel 87...
Page 102: ...Figure 5 7 Calibration Panel Figure 5 8 Firmware Panel 90...
Page 103: ...Figure 5 9 Modulation Panel 91...
Page 123: ...Figure B 1 Information Panel Figure B 2 Configure Panel 111...
Page 124: ...Figure B 3 Reboot in Progress Panel Figure B 4 Web Control Panel 112...