Examples:
CALIBRATE:SCALE:CURRENT 375.0
CAL:SCAL:CURR 375.0
Query Syntax:
CALibrate:SCALe:CURRent? <>
Returned Parameters: <NR3>
Related Commands: None
4.3.9.6 CAL:SCAL:INP
This command sets the full scale external programming inputs for voltage, current, over voltage
trip, and over current trip. The scaling factor for the programming inputs must match the scaling
factor set with hardware on the control board.
Command Syntax:
CALibrate:SCALe:INPut <NRf>
Examples:
CALIBRATE:SCALE:INPUT 10.0
CAL:SCAL:INP 10.0
Query Syntax:
CALibrate:SCALe:INPut? <>
Returned Parameters: <NR3>
Related Commands: None
4.3.9.7 CAL:DEF
This command sets the calibration potentiometers to the factory defaults.
Command Syntax:
CALibrate:DEFaults <>
Examples:
CALibrate:DEFaults
CAL:DEF
Query Syntax:
None
Related Commands: None
4.3.9.8 CAL:STOP
This command terminates the calibration subsystem.
Command Syntax:
CALibrate:STOP <>
62
Summary of Contents for XR III series
Page 1: ...OPERATING AND SERVICE MANUAL XR SERIES III DC POWER SUPPLIES...
Page 2: ......
Page 3: ...MAGNA POWER ELECTRONICS INC 39 ROYAL ROAD FLEMINGTON NJ 08822 February 20 2012...
Page 4: ......
Page 88: ...Figure 4 1 Status Byte Generation Figure 4 2 ESE and ESR Generation 76...
Page 95: ...IEEE Standard CLS ESR ESE STB SRE IDN SAV RCL RST Notes 1 C command Q query 83...
Page 97: ...Figure 5 1 Configuration setup Figure 5 2 GPIB communications setup 85...
Page 99: ...Figure 5 4 Virtual Control Panel Figure 5 5 Command Panel 87...
Page 102: ...Figure 5 7 Calibration Panel Figure 5 8 Firmware Panel 90...
Page 103: ...Figure 5 9 Modulation Panel 91...
Page 123: ...Figure B 1 Information Panel Figure B 2 Configure Panel 111...
Page 124: ...Figure B 3 Reboot in Progress Panel Figure B 4 Web Control Panel 112...