12 - 57
MELSEC-Q
12 CONTROL SUB FUNCTIONS
[2] Step mode
In step operations, the timing for stopping the control can be set. This is called
the "step mode". (The "step mode" is set in the control data "
Cd.34
Step
mode".)
The following shows the two types of "step mode" functions.
(1) Deceleration unit step
The operation stops at positioning data requiring automatic deceleration. (A
normal operation will be carried out until the positioning data requiring
automatic deceleration is found. Once found, that positioning data will be
executed, and the operation will then automatically decelerate and stop.)
(2) Data No. unit step
The operation automatically decelerates and stops for each positioning
data. (Even in continuous path control, an automatic deceleration and stop
will be forcibly carried out.)
[3] Step start information
Control stopped by a step operation can be continued by setting "step continue"
(to continue the control) in the "step start information". (The "step start
information" is set in the control data "
Cd.36
Step start information".)
The following table shows the results of starts using the "step start information"
during step operation.
Stop status in the step
operation
Md.26
Axis operation
status
Cd.36
Step start
information
Step start results
1 step of positioning
stopped normally
Step standing by
1: Step continue
The next positioning data is executed.
The warnings "Step not possible (warning code: 511)" will occur if the "
Md.26
Axis operation status" is as shown below or the step valid flag is OFF when step
start information is set.
Md.26
Axis operation status
Step start results
Standing by
Stopped
In interpolation
In JOG operation
In manual pulse generator operation
Analyzing
Waiting for special start
In OPR
In position control
In speed control
In speed control of speed-position switching control
In position control of speed-position switching control
In speed control of position-speed switching control
In position control of position-speed switching control
Step not continued by warning
Summary of Contents for QD75M1
Page 17: ...MEMO...
Page 71: ...3 20 MELSEC Q 3 SPECIFICATIONS AND FUNCTIONS MEMO...
Page 87: ...4 16 MELSEC Q 4 INSTALLATION WIRING AND MAINTENANCE OF THE PRODUCT MEMO...
Page 98: ...5 11 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 104: ...5 17 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 108: ...5 21 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 112: ...5 25 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 122: ...5 35 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 134: ...5 47 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 178: ...5 91 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 184: ...5 97 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 190: ...5 103 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 249: ...5 162 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 270: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 271: ...6 22 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 272: ...6 23 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 273: ...6 24 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 274: ...6 25 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 275: ...6 26 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 276: ...6 27 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 277: ...6 28 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 278: ...6 29 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 279: ...6 30 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 280: ...6 31 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 281: ...6 32 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 282: ...6 33 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 283: ...6 34 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 284: ...6 35 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 285: ...6 36 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 286: ...6 37 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 287: ...6 38 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 288: ...6 39 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 289: ...6 40 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 290: ...6 41 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 291: ...6 42 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 292: ...6 43 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 293: ...6 44 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 294: ...6 45 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 295: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 296: ...6 47 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 297: ...6 48 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 298: ...6 49 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 299: ...6 50 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 300: ...6 51 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 301: ...6 52 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 328: ...7 7 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 332: ...7 11 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 339: ...MEMO...
Page 529: ...11 36 MELSEC Q 11 MANUAL CONTROL MEMO...
Page 621: ...12 92 MELSEC Q 12 CONTROL SUB FUNCTIONS MEMO...
Page 647: ...14 18 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO...
Page 755: ...Appendix 2 MELSEC Q APPENDICES MEMO...
Page 758: ...Appendix 5 MELSEC Q APPENDICES Axis address mm inch degree PLS Axis address mm inch degree PLS...
Page 879: ...Index 14 MEMO...