14 - 16
MELSEC-Q
14 DEDICATED INSTRUCTIONS
[Functions]
(1) This dedicated instruction is used to return the setting data set in the QD75 buffer
memory and flash ROM to their factory-set data (initial values).
Setting data
Basic parameters (
Pr.1
to
Pr.10
)
Detailed parameters (
Pr.11
to
Pr.42
, Pr.200 , Pr.201 )
OPR basic parameters (
Pr.43
to
Pr.48
)
OPR detailed parameters (
Pr.49
to
Pr.57
)
Servo parameters ( Pr.100 to Pr.161 )
Positioning data (No.1 to 600)
Block start data (No.7000 to 7004)
(2) The PINIT instruction completion can be confirmed using the complete devices
((D)+0) and ((D)+1).
(a) Complete device ((D)+0)
This device is turned ON by the END processing of the scan for which PINIT
instruction is completed, and turned OFF by the next END processing.
(b) Complete state display device ((D)+1)
This device is turned ON and OFF according to the state in which PINIT
instruction is completed.
• When completed normally
: Kept unchanged at OFF.
• When completed abnormally : This device is turned ON by the END
processing of the scan for which PINIT
instruction is completed, and turned OFF by
the next END processing. (same ON/OFF
operation as complete device).
END
processing
END
processing
END
processing
END
processing
OFF
OFF
OFF
ON
ON
ON
When
completed
abnormally
When
completed normally
1 scan
PINIT instruction
execution completion
Sequence program
PINIT instruction
Complete device
Complete state display
device
[Errors]
(1) When a dedicated instruction is completed abnormally, the error complete signal
((D)+1) is turned ON, and the error code is stored in the complete status ((S)+1).
Check and take measures against the error referring to section 15.2 List of error
codes.
Summary of Contents for QD75M1
Page 17: ...MEMO...
Page 71: ...3 20 MELSEC Q 3 SPECIFICATIONS AND FUNCTIONS MEMO...
Page 87: ...4 16 MELSEC Q 4 INSTALLATION WIRING AND MAINTENANCE OF THE PRODUCT MEMO...
Page 98: ...5 11 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 104: ...5 17 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 108: ...5 21 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 112: ...5 25 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 122: ...5 35 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 134: ...5 47 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 178: ...5 91 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 184: ...5 97 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 190: ...5 103 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 249: ...5 162 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 270: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 271: ...6 22 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 272: ...6 23 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 273: ...6 24 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 274: ...6 25 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 275: ...6 26 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 276: ...6 27 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 277: ...6 28 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 278: ...6 29 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 279: ...6 30 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 280: ...6 31 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 281: ...6 32 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 282: ...6 33 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 283: ...6 34 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 284: ...6 35 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 285: ...6 36 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 286: ...6 37 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 287: ...6 38 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 288: ...6 39 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 289: ...6 40 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 290: ...6 41 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 291: ...6 42 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 292: ...6 43 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 293: ...6 44 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 294: ...6 45 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 295: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 296: ...6 47 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 297: ...6 48 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 298: ...6 49 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 299: ...6 50 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 300: ...6 51 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 301: ...6 52 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 328: ...7 7 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 332: ...7 11 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 339: ...MEMO...
Page 529: ...11 36 MELSEC Q 11 MANUAL CONTROL MEMO...
Page 621: ...12 92 MELSEC Q 12 CONTROL SUB FUNCTIONS MEMO...
Page 647: ...14 18 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO...
Page 755: ...Appendix 2 MELSEC Q APPENDICES MEMO...
Page 758: ...Appendix 5 MELSEC Q APPENDICES Axis address mm inch degree PLS Axis address mm inch degree PLS...