15 - 22
MELSEC-Q
15 TROUBLESHOOTING
Classification
of errors
Error
code
Error name
Error
Operation status at error occurrence
Positioning
operation
errors
546
Illegal setting of ABS
direction in unit of
degree
The setting value of ABS direction in
the unit of degree is as follows.
• Set outside the setting range.
• A figure other than "0" is set when
the software stroke limit is valid.
At start: The system will not operate.
During operation:
The system decelerates to a
stop.
(Note that, in the continuous
positioning control and continuous
path control, the system continues
operating with the setting set at the
time of start even if the setting is
changed during the operation.)
800 Hold
error
In the PLC CPU unit parameter
"Output at error stop", the setting for
QD75 is "Hold".
At start: The system will not operate.
During operation:
The system stops with the
setting (deceleration
stop/sudden stop) of the
detailed parameter 2 sudden
stop selection
(stop group 3).
(Note that the deceleration stop only
occurs during the manual pulse
generator operation.)
801
Flash ROM write
error
Data is not written to the flash ROM.
802
Flash ROM sum
check error
While data is written to the flash
ROM, the power is turned OFF.
At start: The system will not operate.
803
PLC CPU error
The PLC CPU has an error.
804
Dedicated instruction
parameter error
The value of a parameter used for
the dedicated instruction is
erroneous.
At start: The system will not operate.
During operation:
The system stops with the
setting (deceleration
stop/sudden stop) of the
detailed parameter 2 sudden
stop selection
(stop group 3).
(Note that the deceleration stop only
occurs during the manual pulse
generator operation.)
805
Flash ROM write
number error
Data is written to the flash ROM
continuously 25 times or more from
the sequence program.
I/F
errors
806
Dedicated instruction
I/F error
Mismatching occurs between the
PLC CPU and QD75.
At start: The system will not operate.
Summary of Contents for QD75M1
Page 17: ...MEMO...
Page 71: ...3 20 MELSEC Q 3 SPECIFICATIONS AND FUNCTIONS MEMO...
Page 87: ...4 16 MELSEC Q 4 INSTALLATION WIRING AND MAINTENANCE OF THE PRODUCT MEMO...
Page 98: ...5 11 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 104: ...5 17 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 108: ...5 21 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 112: ...5 25 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 122: ...5 35 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 134: ...5 47 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 178: ...5 91 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 184: ...5 97 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 190: ...5 103 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 249: ...5 162 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 270: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 271: ...6 22 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 272: ...6 23 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 273: ...6 24 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 274: ...6 25 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 275: ...6 26 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 276: ...6 27 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 277: ...6 28 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 278: ...6 29 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 279: ...6 30 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 280: ...6 31 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 281: ...6 32 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 282: ...6 33 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 283: ...6 34 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 284: ...6 35 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 285: ...6 36 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 286: ...6 37 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 287: ...6 38 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 288: ...6 39 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 289: ...6 40 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 290: ...6 41 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 291: ...6 42 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 292: ...6 43 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 293: ...6 44 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 294: ...6 45 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 295: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 296: ...6 47 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 297: ...6 48 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 298: ...6 49 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 299: ...6 50 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 300: ...6 51 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 301: ...6 52 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 328: ...7 7 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 332: ...7 11 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 339: ...MEMO...
Page 529: ...11 36 MELSEC Q 11 MANUAL CONTROL MEMO...
Page 621: ...12 92 MELSEC Q 12 CONTROL SUB FUNCTIONS MEMO...
Page 647: ...14 18 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO...
Page 755: ...Appendix 2 MELSEC Q APPENDICES MEMO...
Page 758: ...Appendix 5 MELSEC Q APPENDICES Axis address mm inch degree PLS Axis address mm inch degree PLS...
Page 879: ...Index 14 MEMO...