5 - 113
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Default value
Storage buffer memory address (common to axes 1 to 4)
0000
H
0000
H
0000
0000
1287
15
1288
1289
1290
1291
14
1282
1283
1284
1285
1286
13
1277
1278
1279
1280
1281
12
1272
1273
1274
1275
1276
11
1267
1268
1269
1270
1271
10
1262
1263
1264
1265
1266
9
1257
1258
1259
1260
1261
8
1252
1253
1254
1255
1256
7
1247
1248
1249
1250
1251
6
1242
1243
1244
1245
1246
5
1237
1238
1239
1240
1241
4
1232
1233
1234
1235
1236
3
1227
1228
1229
1230
1231
2
1222
1223
1224
1225
1226
1
1217
1218
1219
1220
1221
Pointer No. 0
Pointer No.
Item
Buffer memory address
1212
1213
1214
1215
1216
St
a
rt
ing
hi
st
o
ry
Md.3
Start information
Md.4
Start No.
1292
Md.8
Pointer
Md.5
Start hour
Md.6
Start min: sec
Md.7
Error judgement
Indicates a pointer No. that is next to the Pointer No.
assigned to the latest of the existing starting history records.
Each group of buffer memory addresses storing a complete starting history
record is assigned a pointer No.
Example: Pointer No. 0 = Buffer memory addresses 1212 to 1216
Pointer No. 1 = Buffer memory addresses 1217 to 1221
Pointer No. 2 = Buffer memory addresses 1222 to 1226
Pointer No. 15 = Buffer memory addresses 1287 to 1291
Each history record is assigned a pointer No. in the range between 0 and 15.
If the pointer No. 15 has been assigned to a new record, the next record will
be assigned the pointer number 0.
(A new record replaces an older record when a pointer No. is reassigned.)
Summary of Contents for QD75M1
Page 17: ...MEMO...
Page 71: ...3 20 MELSEC Q 3 SPECIFICATIONS AND FUNCTIONS MEMO...
Page 87: ...4 16 MELSEC Q 4 INSTALLATION WIRING AND MAINTENANCE OF THE PRODUCT MEMO...
Page 98: ...5 11 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 104: ...5 17 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 108: ...5 21 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 112: ...5 25 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 122: ...5 35 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 134: ...5 47 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 178: ...5 91 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 184: ...5 97 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 190: ...5 103 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 249: ...5 162 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 270: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 271: ...6 22 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 272: ...6 23 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 273: ...6 24 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 274: ...6 25 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 275: ...6 26 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 276: ...6 27 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 277: ...6 28 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 278: ...6 29 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 279: ...6 30 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 280: ...6 31 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 281: ...6 32 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 282: ...6 33 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 283: ...6 34 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 284: ...6 35 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 285: ...6 36 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 286: ...6 37 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 287: ...6 38 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 288: ...6 39 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 289: ...6 40 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 290: ...6 41 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 291: ...6 42 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 292: ...6 43 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 293: ...6 44 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 294: ...6 45 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 295: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 296: ...6 47 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 297: ...6 48 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 298: ...6 49 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 299: ...6 50 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 300: ...6 51 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 301: ...6 52 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Page 328: ...7 7 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 332: ...7 11 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 339: ...MEMO...
Page 529: ...11 36 MELSEC Q 11 MANUAL CONTROL MEMO...
Page 621: ...12 92 MELSEC Q 12 CONTROL SUB FUNCTIONS MEMO...
Page 647: ...14 18 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO...
Page 755: ...Appendix 2 MELSEC Q APPENDICES MEMO...
Page 758: ...Appendix 5 MELSEC Q APPENDICES Axis address mm inch degree PLS Axis address mm inch degree PLS...
Page 879: ...Index 14 MEMO...