MI 3321 MultiservicerXA
Single tests in PAT testing mode
71
Result screens:
Examples of Insulation W-PE measurement results
Displayed results:
Main result ............. Insulation resistance W-PE
Note
:
Consider displayed warnings before starting measurement!
6.3.4
Insulation resistance (supply circuit to welding circuit)
The insulation resistance test checks the resistance between primary supply circuit and
the welding circuit (outputs) of the welding machine.
The instrument measures the insulation resistance between:
-
mains test socket‘s live terminals and W1/ W2_TOUCH terminals on 3-phase
adapter (A1422).
Insulation LN-W menu
Test parameters for insulation resistance LN-W measurement
OUTPUT
Test
voltage
[500 V]
LIMIT
Minimum resistance
[5.00 M
, 10.0 M
, none]
TIME
Measuring time
[5 s, 10 s, 30 s, 60 s, 120 s, none]
Test circuit and measurement procedure for insulation resistance LN-W
measurement
For more information refer to chapter
Measurements according to IEC/ EN
60974-4
, paragraph
Insulation resistance (supply circuit to welding circuit)
in
3-phase adapter Instruction manual.