MEP 660 - Trouble shooting Manual
Doc No.: IM – 51
Rev.2.0
Print: October 2008
29
PARAMETER
DESCRIPTION
FAULT CODE
1023
FAULT MESSAGE BKT Stuck in Braking. Run Auto/Manual Test.
Can’t Motor: Electrical Control Problem
RESTRICTIONS
Motoring Prohibited
ALARM BELL
30 Sec.
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
RECOVERY
Autometic when BKT stuck is cleared
PROBABLE
CAUSES
1. Control Air pressure is less or zero.
2. Foreign particles fallen in Paul assembly.
3. BKT motoring side magnet valve is defective.
4. Air leaking from the Air cylinder gasket.
5. Air hose connection to magnet valve given up.
FAULT
ISOLATION
1. Check control air pressure in the nose compartment. It should be
5kg/Cm.
2
.
A. If it is less adjust the pressure.
B. If it is zero, check and attend air brake system.
2. Operate BKT manually with ‘L’ rod.
A. If BKT is not operating manually, then
a) Inspect Paul assembly for any foreign particles inside the
Rack and pinion teeth. Check and attend.
b) Inspect other operatig mechanism for any disorders or
broken iolite bushes etc. Replace wherever necessary.
c) Check for any main contacts welding. Inspect and replace if
necessary.
3. If BKT is operating manually, and control air pressure is 5 Kg/Cm
2
operate the BKT through magnetvalves by pressing manual levers /
armature plates on both Motoring and Braking side magnetvalves.
A. If BKT is not operating, then
a) Check which magnet valve is defective and replace.
b) Check for any air leakages through air engine gaskets and
replace the gaskets.
c) Check for any damged piston buckets and replace.
4. If BKT is operating through magnetvalves, set up the display mode
to “Manual Tests for outputs” under Test Mode menu by pressing
the following keys.
5. ‘Menu’ + 3 + (Pass code) + 3 + ‘Enter’ + 09 + ‘Enter’ + 1 to
operate magnet valve of BKT motoring side.
6. If the BKT is not operated to motoring side, then
A. Check the voltage at the operating coil of BKT motoring side
magnet valve.
B. If the Voltage is > 65V, then the operating coil is open circuited
internally. Replace amgnet valve.
C. If the Voltage is zero, check the voltage between wire terminal 6
on the BKT motoring magnet valve and 4 wire.
D. If the voltage is zero, 6 wire loop coming to BKT motoring side
magnet valve is open circuited. Check and replace.
E. If voltage is > 65V, then positive supply is available but
negative supply through MEP-660 is missing.