MEP 660 - Trouble shooting Manual
Doc No.: IM – 51
Rev.2.0
Print: October 2008
256
PARAMETER
DESCRIPTION
FAULT CODE
1255
FAULT MESSAGE
Memory Card of Event Recorder Faulty
RESTRICTIONS
--
ALARM BELL
--
RESET LEVEL
Automatic when system detected as new memory card loaded for
event recording.
FAULT
RECOVERY
LOW, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
PROBABLE
CAUSES
1. Memory card faulty.
FAULT
ISOLATION
Replace the memory card with new memory card for Event recording
purpouse.
PARAMETER
DESCRIPTION
FAULT CODE
1260
FAULT MESSAGE
Brake Pipe Pr. Sensor Faulty
RESTRICTIONS
--
ALARM BELL
--
RESET LEVEL
MEDIUM, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
RECOVERY
Automatic when the Brake Pipe Pressure sensor found working normal.
PROBABLE
CAUSES
1. Defective / blocked pressure pipelines.
2. Defective Brake Pipe Presure sensor (BPP).
3. Defective cables
4. Defective ADB4
5. Defective MIAI card in slot 2.
FAULT
ISOLATION
1. Set the display to show mixed parameters by selecting ‘Display’
mode from the main menu and then selecting ‘Mixed’ sub-menu.
2. Check the brake pipe pressure displayed in the display unit with
the gauge on control stand.
3. If the difference is excess, replace the sensor and check up.
4. If the difference is negligible but still the fault is logging:
A. Check Slackness of the connectors either at the sensor or at the
ADB4. Tighten the connectors both at the sensor and ADB of the
cable ID: BI.
B. Defective interconnecting cable ID: BI between sensor and ADB.
Replace the cable and check up.
C. Slackness of the connectors either at ADB4 or MEP-660 control
unit. Tighten the cable connectors both at ADB4 and MEP-660
control unit for the cable ID: BJ.
D. Defective interconnecting cable ID: BJ between ADB and MEP-
660 control unit.
E. Defective ADB4. Replace the ADB4 and check.
F. Defective MIAI card in slot 2. Replace the card check up.